7-25
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-16-5. Detail Level Adjustment (16:9)
16:9 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.
On the setup menu, set as follows.
PAGE
: S12
*
FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1
Lens IRIS
Spec.
: A = 80
±
2 IRE (NTSC)
A = 560
±
14 mV (PAL)
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
Select the 16:9 mode.
PAGE
: S14
*
WIDE SCREEN
ITEM
: 16:9/4:3 MODE
→
16:9
2.
On the setup menu, adjust as follows.
PAGE
: S16
*
LEVEL 1
ITEM
: DETAIL LVL (Factory setting: 0)
Spec.
: Adjust to the detail amount which is
added to each step in the grayscale
chart for the customer’s preferences.
7-16-6. Knee Aperture Adjustment (16:9)
16:9 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.
On the setup menu, set as follows.
PAGE
: S12
*
FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
PAGE
: S17
*
LEVEL 2
ITEM
: KNEE APT.
→
ON
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
.
GAIN switch (inside panel)
→
M (9 dB)
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
Select the 16:9 mode.
PAGE
: S14
*
WIDE SCREEN
ITEM
: 16:9/4:3 MODE
→
16:9
2.
On the setup menu, adjust as follows.
PAGE
: S17
*
LEVEL 2
ITEM
: K.APT.LVL
Spec.
: Adjust the peak-to-peak level of the
noise at the third steps from the top
(portion B) in the grayscale chart, as
desired. (Reference level is 40 mV)
A
A
7-16. Detail Signal Adjustment (16:9)
B