7-23
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-16. Detail Signal Adjustment (16:9)
7-16-1. Crispening Adjustment (16:9)
16:9 mode
Preparation
.
On the setup menu, set as follows.
PAGE
: S12
*
FUNCTION 1/2
ITEM
: DETAIL
→
ON
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
Adjustment Procedure
Equipment : Black and white monitor
Test point : TEST OUT connector
1.
Select the 16:9 mode.
PAGE
: S14
*
WIDE SCREEN
ITEM
: 16:9/4:3 MODE
→
16:9
2.
On the setup menu, adjust as follows.
PAGE
: S16
*
LEVEL 1
ITEM
: CRISPENING
Spec.
: Reduce the noise at gray portion to a
permissible level.
7-16-2. Level Depandent Adjustment (16:9)
16:9 mode
Preparation
.
On the setup menu, set as follows.
PAGE
: S12
*
FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
PAGE
: S16
*
LEVEL 1
ITEM
: LVL DEPEND
→
ON
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1
Lens IRIS
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
Adjustment Procedure
Equipment : Waveform monitor
Test point : TEST OUT connector
1.
Select the 16:9 mode.
PAGE
: S14
*
WIDE SCREEN
ITEM
: 16:9/4:3 MODE
→
16:9
2.
On the setup menu, adjust as follows.
PAGE
: S16
*
LEVEL 1
ITEM
: L.DEP.LVL
Spec.
: Eliminate the detail signal from portion
B.
Note
After this adjustment, be sure to perform Section 7-16-4
“H/V Ratio Adjustment (16:9)”, and Section 7-16-5
“Detail Level Adjustment (16:9)”, in that order.
A
B
7-16. Detail Signal Adjustment (16:9)
A