5-22
DCR-IP5/IP5E/IP7BT/IP7E
11. LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart (Color reproduction
adjustment frame) Note1
Measurement Point
Display data of page 1 (Note3)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 46 to 49
Specified Value
0FF0 to 1010
Note1:
Refer to “11. Picture Frame Setting”.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3:
This adjustment should be carried out upon completion of the F
No. & ND light quantity standard data input.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
LV data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
0D
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
10
2E
Set the data, and press PAUSE
button.
5
1
Check that the display data (Note4)
satisfies the specified value.
6
6
01
00
Set the data, and press PAUSE
button.
7
6
3F
10
Set the data.
8
6
01
85
Set the data, and press PAUSE
button.
9
6
02
Check that the data changes to
“01”. (Note6)
Note5:
The adjustment data will be automatically input to page: E, address:
1E, 1F.
Note6:
The adjustment data will be automatically input to page: E, address:
46 to 49.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
F
10
00
Set the data, and press PAUSE
button.
3
6
3F
00
Set the data.
4
0
01
00
Set the data.
10. Mechanical Shutter Adjustment
(DCR-IP7BT/IP7E)
Adjust the period which the mechanical shutter is closed, and
compensate the exposure.
Adjustment Page
F
7
Adjustment Address
70 to 84
1D to 20
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 70 to 84.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Input the following data to page: 7, addresses: 1D to 20.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
4)
Select page: 0, address: 01, and set data: 00.
Address
1D
1E
1F
20
Data
7A
80
80
7F
Address
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
Data
BD
09
6F
07
77
06
A6
05
43
04
E5
58
2B
6D
D9
6D
4D
5D
D9
40
22
Содержание DCR-IP5 MovieShaker v3.1
Страница 97: ...DCR IP5 IP5E IP7BT IP7E 4 58 4 57 B W EVF VF 149 ...
Страница 122: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 152 OPTICAL AXIS FRAME DCR IP5 IP5E IP7BT IP7E ...
Страница 124: ...Sony EMCS Co DCR IP5 IP5E IP7BT IP7E 154 9 929 923 31 2005I1600 1 2005 09 Published by DI Technical Support Department ...
Страница 127: ...5 1 SECTION 5 ADJUSTMENTS DCR IP5 IP5E IP7BT IP7E ...
Страница 187: ...DCR IP5 IP5E IP7BT IP7E Sony EMCS Co 64 9 929 923 81 2001L1600 1 2001 12 Published by DI Customer Center ...