5-17
DCR-IP5/IP5E/IP7BT/IP7E
4. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measurement Point
Display data of page: F, address: 63,
65
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
4A to 4F, 5A to 5E, 60 to 63, 65
Specified Value
Data of address 63: 00 to 0E
Upper digit of address 65 data: 0 to A
Lower digit of address 65 data: 0 to A
Note1:
Dark Siemens star chart.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3:
This adjustment should be carried out upon completion of the
following adjustments.
HALL adjustment, MR adjustment
Switch setting:
POWER .................................................................. CAMERA
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note:
The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage:
The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
6
01
27
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note4)
5
F
63
Check that the data is “00” to
“0E”.
6
F
65
Check that the upper digit of the
data is “0” to “A”.
7
F
65
Check that the lower digit of the
data is “0” to “A”.
Note4:
The adjustment data will be automatically input to page: F, address::
4A to 4F, 5A to 5E, 60 to 63, 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”.
Minipattern box
Below 3 cm
Camcorder
Camera
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage
±
0.01Vdc
Output current : more than 3.5A
Fig. 5-1-7.
Содержание DCR-IP5 MovieShaker v3.1
Страница 97: ...DCR IP5 IP5E IP7BT IP7E 4 58 4 57 B W EVF VF 149 ...
Страница 122: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 152 OPTICAL AXIS FRAME DCR IP5 IP5E IP7BT IP7E ...
Страница 124: ...Sony EMCS Co DCR IP5 IP5E IP7BT IP7E 154 9 929 923 31 2005I1600 1 2005 09 Published by DI Technical Support Department ...
Страница 127: ...5 1 SECTION 5 ADJUSTMENTS DCR IP5 IP5E IP7BT IP7E ...
Страница 187: ...DCR IP5 IP5E IP7BT IP7E Sony EMCS Co 64 9 929 923 81 2001L1600 1 2001 12 Published by DI Customer Center ...