Flange Back Adjustment
(Using the flange back adjustment chart and
Subject More than 500 m Away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
3-1. Flange Back Adjustment (1)
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 2B, 3E
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
3) Check that the data on page: F, address: 18 to 2B and 3E are
initial value (See table below).
Address
Data
Address
Data
Address
Data
18
22
1F
00
26
23
19
48
20
00
27
44
1A
2D
21
00
28
0A
1B
3A
22
12
29
00
1C
13
23
00
2A
00
1D
00
24
20
2B
00
1E
00
25
20
3E
FF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
6
01
13
Press PAUSE button.
4
6
01
15
Press PAUSE button.
(Note 2)
5
6
02
Check the data changes to
“01”.
6
F
3E
Check the data.
00: Normal
01 to FF: Defective
Note 2:
The adjustment data will be automatically input to page:
F, address: 18 to 2B and 3E.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2.
(Refer to page 5-13)
3
0
01
00
4
Perform “Flange Back
Adjustment (2)”.
3-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Mode
CAMERA
Subject
Subject more than 500 m away
(Subject with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 2B, 3E
Adjusting method:
Order Page Address Data
Procedure
1
Set the zoom lens to the
TELE end and expose a
subject that is more than 500
m away. (Note 1)
2
0
01
01
3
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
4
6
01
13
Press PAUSE button.
5
Place ND filter on the lens so
that the optimum image is
obtain.
6
6
01
29
Press PAUSE button.
(Note 2)
7
6
02
Check the data changes to
“01”.
8
F
3E
Check the data.
00: Normal
01 to FF: Defective
Note 1:
Subject with clear contrast such as building, etc.
Nearby subjects less than 500 m away should not be in
the screen.
Note 2:
The adjustment data will be automatically input to page:
F, address: 18 to 2B and 3E.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 3.
(Refer to page 5-13)
3
0
01
00
4
Perform “Flange Back
Check”.
Содержание Cyber-shot DSC-F707
Страница 57: ...DSC F707 38 1 2 4 37 4 38 DC CONTROL FRONT CONTROL AUDIO VIDEO AMP CONNECTION FR 181 ...
Страница 63: ...DSC F707 A A K K K K A K K 4 49 4 50 LCD DRIVE TIMING GENERATOR PD 155 ...
Страница 136: ... 168 Sony EMCS Co DSC F707 9 929 915 32 2004I0500 1 2004 9 Published by DI Customer Center ...