![Sony Cyber-shot DSC-F707 Скачать руководство пользователя страница 87](http://html.mh-extra.com/html/sony/cyber-shot-dsc-f707/cyber-shot-dsc-f707_service-manual_393196087.webp)
5-13
DSC-F707
1-4.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied.
Note:
For “CAMERA SYSTEM ADJUSTMENTS”, perform in
order of item numbers.
Data setting during camera system adjustments
Perform the following data setting before the camera system ad-
justments.
Set up setting:
1) VIDEO OUT of SET UP setting............... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't
set the SET UP setting to “PAL”)
Data setting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
10
80
Press PAUSE button.
3
2
10
Check the bit values of bit3,
bit4 and bit5 are “1”.
(Note 1, 2)
4
D
11
40
Press PAUSE button.
5
D
10
81
Press PAUSE button.
5
6
C1
Check the data changes to
“02”.
6
4
06
01
7
6
6C
01
8
Wait for 1 second.
9
E
5C
28
Press PAUSE button.
10
E
97
00
Press PAUSE button.
11
E
B7
00
Press PAUSE button.
12
E
BB
00
Press PAUSE button.
13
E
CD
08
Press PAUSE button.
Note 1
: For the bit values, refer to “5-2. SERVICE MODE”,
“2-3. 2. Bit value discrimination”.
Note 2:
In case of wrong data, select page: 2, address: 0A and set
data: 02.
Set the adjusting remote commander to normal LANC,
and the power will be turned off and on automatically.
Wait for more than 0.167 second after the power on, and
set the adjusting remote commander to the service LANC.
Then, retry from the step 1.
Note 3:
Repeat the “Data setting method”, if the power was turned
off and on during the “CAMERA SYSTEM ADJUST-
MENTS”.
After completing the camera system adjustments,
release the data setting:
Order Page Address Data
Procedure
1
4
06
00
2
6
6C
00
3
E
97
10
Press PAUSE button.
4
E
CD
00
Press PAUSE button.
5
D
11
00
Press PAUSE button.
6
D
10
00
Press PAUSE button.
7
0
01
00
1.
HALL Adjustment
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 1
(Note 2)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
5E, 5F, 61, 62
Specified value
12 to 16 during IRIS OPEN
76 to 7A during IRIS CLOSE
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right two digits of the page: 1 displayed data of the
adjusting remote commander.
1:00:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustment”.
3
6
94
14
4
6
95
78
5
6
01
6D
Press PAUSE button.
(Note 3)
6
6
02
Check the data changes to
“01”.
7
6
01
00
Press PAUSE button.
8
0
03
03
9
6
01
01
Press PAUSE button.
10
1
Check that the displayed data
(Note 2) during IRIS OPEN
satisfied the specified value.
11
6
01
03
Press PAUSE button.
12
1
Check that the displayed data
(Note 2) during IRIS CLOSE
satisfied the specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 5E, 5F, 61, and 62.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
94
00
3
6
95
00
3
0
03
00
4
Release the data setting
performed at step 2.
5
0
01
00
Содержание Cyber-shot DSC-F707