![Sony Cyber-shot DSC-F707 Скачать руководство пользователя страница 88](http://html.mh-extra.com/html/sony/cyber-shot-dsc-f707/cyber-shot-dsc-f707_service-manual_393196088.webp)
5-14
DSC-F707
2.
Flange Back Adjustment
(Using the minipattern box)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode
CAMERA
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 2B, 3E
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 3:
The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage
±
0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
6) Check that the data on page: F, address: 18 to 2B and 3E are
initial value (See table below).
Address
Data
Address
Data
Address
Data
18
22
1F
00
26
23
19
48
20
00
27
44
1A
2D
21
00
28
0A
1B
3A
22
12
29
00
1C
13
23
00
2A
00
1D
00
24
20
2B
00
1E
00
25
20
3E
FF
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Below 3 cm
Camera
Camera
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage
±
0.01 Vdc
Output current : more than 3.5 A
Fig. 5-1-12
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
6
01
13
Press PAUSE button.
4
6
01
27
Press PAUSE button.
(Note 4)
5
6
02
Check the data changes to
“01”.
6
F
3E
Check the data.
00: Normal
01 to FF: Defective
Note 4:
The adjustment data will be automatically input to page:
F, address: 18 to 2B and 3E.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2.
(Refer to page 5-13)
3
0
01
00
4
Perform “Flange Back
Check”.
Содержание Cyber-shot DSC-F707
Страница 57: ...DSC F707 38 1 2 4 37 4 38 DC CONTROL FRONT CONTROL AUDIO VIDEO AMP CONNECTION FR 181 ...
Страница 63: ...DSC F707 A A K K K K A K K 4 49 4 50 LCD DRIVE TIMING GENERATOR PD 155 ...
Страница 136: ... 168 Sony EMCS Co DSC F707 9 929 915 32 2004I0500 1 2004 9 Published by DI Customer Center ...