37
Mode
Initialize
x1 speed
x4 speed
x8 speed
x12 –x24(Partial CAV) speed
Tracking servo OFF
Tracking servo ON
PlayAudio (23’47”)
PlayAudio (5’00”)
PlayAudio (55’00”)
PARITY
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
Mode
Test Mode
ID2
ON
ID1
OFF
ID0
ON
PARITY
ON
ID2
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ID1
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ID0
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
5-1-2. Setting Single-Operation of CDM-56 Mechanism
Block
Jig
CD test disc (YEDS-18)
: 3-702-101-01
Single-Operation of CDM-56
1. Chuck the disc beforehand.
2. Set the COMMAND SW of the controller to the test mode.
ID2
ON
ID1
OFF
ID0
ON
PARITY
ON
5-1. TOOLS AND MEASURING INSTRUMENTS
5-1-1. GENERAL AND SPECIAL TOOLS LIST
The tools and measuring instruments for performing maintenance
on the CDM-56 series are listed below.
5-1-1-1. General Tools
SONY Parts No.
⊕
Driver 2mm
(7-700-749-01)
⊕
Driver 2.6mm
(7-700-749-03)
Tweezers
(7-700-753-02)
Round Nose Plier
(7-700-757-01)
Cutter
(7-700-758-02)
Soldering Iron (20W)
Desoldering Metal Braid (Solder Wick)
Multi Meter (DRM)
5-1-1-2. Special Tools
IBM PS/VP System
PS/VP and the monitor (640kbyte RAM, 3.5" FDD, HDD, Video
RAM-CGA or Higher, DOS Ver. 6.2 or later)
SCSI board AVA-2904E that is supplied as an accessory of CDJ-
500 or equivalent.
Active Speaker
SCSI cable (Attached or equal cable)
5-1-1-3. Test Disc
SONY Test Disc (YEDS-18)
(3-702-101-01)
SONY Test Disc (TGRS-21)
(J-2501-110-A)
5-1-1-4. Measuring Equipments
Osilloscope Dual Trace 20MHz (probe x10)
DC Volt Meter (min. 10mA)
5-1-1-5. Software
ATP625 Disc (CDM-001)
(J-2501-173-A)
Field50. EXE Disc (CDJ-001)
(J-2501-172-A) (*NOTE)
Dwn-Aspi. EXE (CDM-002)
(J-2501-176-A) (*NOTE)
Update f. EXE Disc (CDJ-002)
(J-2501-175-A) (*NOTE)
*: marked is refer to SERVICING NOTE
5-1-1-6. Expendable and Chemical Supplies
Cotton Swab (200 pieces)
(7-740-900-65)
Lens Cleaning Liquid
(J-2501-000-A)
Molykote Grease (EM-30L)
(4-918-645-01)
Hanarl (SFL-9)
(7-400-000-00)
SECTION 5
ELECTRICAL ADJUSTMENTS
CNJ201
CDM-56
MAIN BOARD
3. While pressing the TEST button of the MAIN BOARD, turn
on the power of the CDJ-C50S or power supply unit.
4. After about 1 second later, release the TEST button.
5. This sets the test mode. To enter the other mode, refer to the
following table, set the dip switch, and press the TEST button.
Setting of Single-Operation Mode
Command list of Single-Operation Mode
Содержание CDJ-500
Страница 26: ...26 Newly rewritten program version 12 When downloading is finished the following screen appears ...
Страница 70: ...CDJ 500 70 70 7 15 SCHEMATIC DIAGRAM SENSOR SECTION Page 60 Page 66 ...
Страница 71: ...CDJ 500 71 71 7 16 PRINTED WIRING BOARD SENSOR SECTION See page 53 for Circuit Boards Location Page 71 Page 67 ...
Страница 72: ...CDJ 500 72 72 7 17 SCHEMATIC DIAGRAM SCSI SECTION Page 68 Page 74 Page 66 Page 66 ...