MVC-CD250/CD400
5-24
13. Auto White Balance 3200K Check 2
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
A/V OUT jack
(Note 2)
(75
Ω
terminated)
Specified Value
R ratio: 3F60 to 40A0
B ratio: 3F60 to 40A0
R-Y level data: 7C to 84
B-Y level data: 7C to 84
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame set-
ting ”. (Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
6
37
10
6
6
01
0F
Press PAUSE button.
7
6
02
Check the data changes to
“01”.
8
0
03
04
9
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
10
0
03
05
11
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
12
0
03
2E
13
1
Check that the R-Y level data
(Note 2) satisfied the specified
value.
14
0
03
2F
15
1
Check that the B-Y level data
(Note 2) satisfied the specified
value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
37
00
3
6
01
00
Press PAUSE button.
4
6
B6
00
Set data noted down at step 3,
and press PAUSE button.
5
Release the data setting per-
formed at step 1. (Refer to
page 5-14)
14. Auto White Balance 3200K Check 3
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
A/V OUT jack
(Note 2)
(75
Ω
terminated)
Specified Value
R ratio: 3F60 to 40A0
B ratio: 3F60 to 40A0
R-Y level data: 7C to 84
B-Y level data: 7C to 84
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame set-
ting ”. (Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
6
37
12
6
6
01
0F
Press PAUSE button.
7
6
02
Check the data changes to
“01”.
8
0
03
04
9
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
10
0
03
05
11
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
12
0
03
2E
13
1
Check that the R-Y level data
(Note 2) satisfied the specified
value.
14
0
03
2F
15
1
Check that the B-Y level data
(Note 2) satisfied the specified
value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
37
00
3
6
01
00
Press PAUSE button.
4
6
B6
00
Set data noted down at step 3,
and press PAUSE button.
5
Release the data setting per-
formed at step 1. (Refer to
page 5-14)
Содержание CD Mavica MVC-CD250
Страница 33: ...Schematic diagram of the SY 76 board are not shown Pages from 4 15 to 4 40 are not shown ...
Страница 43: ...Printed wiring board of the SY 76 board are not shown Pages from 4 57 to 4 60 are not shown ...
Страница 51: ...Waveforms of the SY 76 board are not shown Pages 4 74 and 4 75 are not shown ...
Страница 55: ...Mounted parts location of the SY 76 board are not shown Page 4 79 is not shown ...
Страница 57: ...MVC CD250 CD400 5 1 COVER COVER SECTION 5 ADJUSTMENTS ...
Страница 121: ...Electrical parts list of the SY 76 board are not shown Pages from 6 15 to 6 23 are not shown ...
Страница 124: ...MVC CD250 CD400 148 Sony EMCS Co 2002D0500 1 2002 4 Published by DI Customer Center 9 929 968 31 ...
Страница 125: ...Revision History 992996831 pdf Reverse Ver 1 0 Date 2002 04 History Official Release Contents S M Rev issued ...