MVC-CD250/CD400
5-27
Order Page Address Data
Procedure
18
1
Check that the B-Y level data
(Note 2) satisfied the specified
value.
19
6
01
00
Press PAUSE button.
20
6
37
14
21
6
01
3F
Press PAUSE button.
22
6
02
Check the data changes to
“01”.
23
0
03
04
24
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
25
0
03
05
26
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
27
0
03
2E
28
1
Check that the R-Y level data
(Note 2) satisfied the specified
value.
29
0
03
2F
30
1
Check that the B-Y level data
(Note 2) satisfied the specified
value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
37
00
3
6
01
00
Press PAUSE button.
4
6
B6
00
Set data noted down at step 4,
and press PAUSE button.
5
Release the data setting per-
formed at step 2. (Refer to
page 5-14)
6
Remove the C14 filter on the
lens.
18. Auto White Balance 5800K Check 1
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of Video terminal of
Page: 1
A/V OUT jack
(Note 2)
(75
Ω
terminated)
Specified Value
MVC-CD250 :
R ratio : 29A0 to 2BA0
B ratio : 6000 to 6200
R-Y level data : 6E to 8E
B-Y lavel data : 6E to 8E
MVC-CD400 :
R ratio : 29E0 to 2B20
B ratio : 5D20 to 5E60
R-Y level data : 6E to 8E
B-Y lavel data : 6E to 8E
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Place the C14 filter on the lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
3
Perform “Picture Frame set-
ting ”. (Refer to page 5-15)
4
6
B6
Note down the data.
5
6
B6
03
6
6
37
13
7
6
01
11
Press PAUSE button.
8
6
38
Check the data changes to
“01”.
9
6
01
C3
Press PAUSE button.
10
6
02
Check the data changes to
“01”.
11
0
03
04
12
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
13
0
03
05
14
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
15
0
03
2C
16
1
Check that the R-Y level data
(Note 2) satisfied the specified
value.
17
0
03
2D
Содержание CD Mavica MVC-CD250
Страница 33: ...Schematic diagram of the SY 76 board are not shown Pages from 4 15 to 4 40 are not shown ...
Страница 43: ...Printed wiring board of the SY 76 board are not shown Pages from 4 57 to 4 60 are not shown ...
Страница 51: ...Waveforms of the SY 76 board are not shown Pages 4 74 and 4 75 are not shown ...
Страница 55: ...Mounted parts location of the SY 76 board are not shown Page 4 79 is not shown ...
Страница 57: ...MVC CD250 CD400 5 1 COVER COVER SECTION 5 ADJUSTMENTS ...
Страница 121: ...Electrical parts list of the SY 76 board are not shown Pages from 6 15 to 6 23 are not shown ...
Страница 124: ...MVC CD250 CD400 148 Sony EMCS Co 2002D0500 1 2002 4 Published by DI Customer Center 9 929 968 31 ...
Страница 125: ...Revision History 992996831 pdf Reverse Ver 1 0 Date 2002 04 History Official Release Contents S M Rev issued ...