The CCU-790/790P Camera Control Unit provides a 
variety of remote control and adjustment functions for the 
processing of signals from a BVP-E10/E10P/E10WS/
E10WSP/E30/E30P/E30WS/E30WSP CCD Color Video 
Camera, and can be used in Electronic Field Production 
(EFP) or studio work. Signal control is performed with an 
optional MSU-900/950 Master Setup Unit or an RCP-750/
751/920/921 Remote Control Panel. 

The CCU-790/790P has the following features:

Wide variety of system configurations

The optional CA-905K/F/T large-lens adaptor allows a 
large lens to be fitted onto the portable video camera and 
used in conjunction with the BVF-77/77CE 7-inch B/W 
Viewfinder.

3 output lines (composite video or SDI can be selected as 
the output signal) are provided.

3 SDI output lines are provided (available only when 
SDI signal output is selected for the VBS/SDI-1 
connector).

The CCU-790/790P supports communications between 
the video camera and the CCU-790/790P over either a 
triax cable or coaxial cable.  (Power, however, is not 
supplied to the video camera in the case of coaxial 
cable.)

When a video camera equipped with the AC OUT 
connector is connected to the CCU-790/790P, the video 
camera can supply power which is supplied from the 
CCU-790/790P to an external device through the AC 
OUT connector. This can be done by the setting on the 
video camera.

For details, refer to the Operation Manual supplied with 
the video camera.

10-MHz, wideband triax transmission

Wideband triax transmission with Y signal at 10 MHz, 
R-Y and B-Y signals at 6 MHz is used for inputting 
video signals from the video camera. The triax cable 
length can be extended from 50 to 1,000 m (with 
Fujikura 

φ

8.5 mm cables), 75 to 1,500 m (with BELDEN 

9232 

φ

13.2 mm cables), or 100 to 2,000 m (with 

Fujikura 

φ

14.5 mm cables).

The CCU-790/790P supports teleprompter signal 
transmission. Teleprompter signals can be transferred 
over distances of 50 to 500 m (with Fujikura 

φ

8.5 mm 

cables), 75 to 750 m (with BELDEN 9232 

φ

13.2 mm 

cables), or 100 to 1,000 m (with Fujikura 

φ

14.5 mm 

cables).

Rack mountable

The CCU-790/790P is three-units high and can be 
mounted in a 19-inch EIA standard rack.

For details on the rack mounting, refer to the System 
Manual.

Production of some of the peripherals and related devices 
described in this manual has been discontinued. For advice 
about choosing devices, please contact your Sony dealer or 
a Sony sales representative.

Note

Содержание CCU-790P

Страница 1: ...CAMERA CONTROL UNIT CCU 790 790P OPERATION MANUAL English 1st Edition Revised 1 ...

Страница 2: ...he State of California USA only Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate Perchlorate Material Lithium battery contains perchlorate For the customers in Europe for CCU 790P This product with the CE marking complies with both the EMC Directive and the Low Voltage Directive issued by the Commission of the European Community Compliance with these d...

Страница 3: ... 11 Settings of the camera 11 Status display of the camera system 11 Self diagnostics of the camera system 11 Settings of the network 12 Self diagnostics results of the CCU 790 790P internal boards 13 Self diagnostics results of the camera internal boards 14 ROM version indication 15 Exiting the Self diagnostic mode 15 When an error occurs 15 Specifications 15 General 15 Input signals 15 Output si...

Страница 4: ...era equipped with the AC OUT connector is connected to the CCU 790 790P the video camera can supply power which is supplied from the CCU 790 790P to an external device through the AC OUT connector This can be done by the setting on the video camera For details refer to the Operation Manual supplied with the video camera 10 MHz wideband triax transmission Wideband triax transmission with Y signal a...

Страница 5: ... a headset f CAMERA POWER switch and indicator This switch controls the power supply to the video camera when the MAIN POWER switch is set to the ON side I position The indicator lights when power is supplied to the video camera If an RCP 750 751 920 921 Remote Control Panel is connected to this unit the CAM PW switch on the panel must be lit for control of the power supply to the camera with this...

Страница 6: ...ctors The REFERENCE INPUT connectors RET 1 connectors and the RET 2 PROMPTER connectors are loop through connectors A REFERENCE INPUT connectors BNC type The upper connector accepts reference signals black burst signal for external synchronization The input signal is output from the lower connector The reference input signal can be terminated at 75 ohms internally To terminate the signal input the...

Страница 7: ...tails consult your Sony service personnel F SPARE connector BNC type Not used d OUTPUT connectors A VBS composite video signal SDI serial digital interface 1 VBS SDI 2 VBS SDI 3 connectors BNC type Supply the signal from the video camera in composite or SDI format Use the switch on the internal board to select the composite video signal or SDI signal For details on the internal boards consult your...

Страница 8: ...t might have excessive voltage to this port Follow the instructions for this port g INTERCOM TALLY PGM program audio connector D sub 25 pin Inputs outputs intercom tally or program audio signals Connects to an intercom tally or program audio connector of an intercom system h MIC REMOTE microphone remote control connector D sub 15 pin Connects to an external control unit such as an audio mixer With...

Страница 9: ...input through the INCOM TALLY PGM connector PROD Producer line PRIV Producer line and engineer line are cut off and communication is possible only between the CCU 790 790P and the camera connected to the rear panel of the CCU 790 790P ENG Engineer line The settings regarding the output intercom signals can be performed on the internal AU board For details consult your Sony service personnel c Head...

Страница 10: ... never be connected to or disconnected from the CCU 790 790P when the power is turned on Always turn the unit off first Video camera Some switches or controls on the video camera may not work when the camera is connected to the CCU 790 790P For details refer to Operation Manuals of the video camera and the camera adaptor The maximum power output from the CAMERA connector of the CCU 790 790P is 360...

Страница 11: ...e ROM version indication page appears a screen with no characters character OFF screen appears When you keep pressing the CHARACTER button pages are automatically turned to the character OFF screen In this manual self diagnostics pages are shown in order of appearance The following illustrations of the self diagnostics pages may differ from the actual indications depending on the settings and conn...

Страница 12: ...mission status of the REMOTE connector RCP CNU Power Power supply status of the REMOTE connector Page 3 Intercom CCU CCU intercom selection Intercom CAMERA CH1 Status of intercom 1 of the camera producer line engineer line Intercom CAMERA CH2 Status of intercom 2 of the camera producer line engineer line CHU MIC Gain Gain and control status of the microphone circuit Settings of the network The fol...

Страница 13: ... CCU 790 790P internal boards For details on the internal boards refer to the System Manual DM board CAM Video Status of the Y R Y and B Y signals of the triax signal Skin Gate Reception status of the Skin gate signal from the camera TRIAX Comp Cable compensation of a triax cable TRIAX Step Compensation step of the triax cable step indication in the circuit The cable length may not be displayed co...

Страница 14: ...mber of the AU board IV board RETURN Input settings for the return channels 1 to 4 MIX Y Setting for camera signal to be mixed with the return signal Power IV board power supply status DIF Power status of the DIF board connected to the rear of the IV board PLD Status of the PLD mounted on the IV board and program version of the PLD BoardID ID number of the IV board EN board Component Setting statu...

Страница 15: ... ON current probe method 90 A 240 V 2 Hot switching inrush current measured in accordance with European standard EN55103 1 20 A 230 V Cable length1 50 to 1 000 m Fujikura φ8 5 mm 75 to 1 500 m BELDEN 9232 φ13 2 mm 100 to 2 000 m Fujikura φ14 5 mm Operating temperature 5 C to 40 C 41 F to 104 F Storage temperature 20 C to 50 C 4 F to 122 F Dimensions 424 133 394 mm 163 4 51 4 155 8 in w h d not inc...

Страница 16: ...or 6 R G B and Y R Y B Y are switchable Camera input output signals CAMERA Triax Kings type for the U S A and Canada Fischer type for Europe COAX BNC type 1 75 ohms REMOTE 8 pin multiconnector ETHERNET IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX INTERCOM TALLY PGM D sub 25 pin 1 4W RTS TALLY 24 V DC TTL level or contact selectable MIC REMOTE D sub 15 pin 1 INCOM on the front panel XLR 5 pin 1 Suppl...

Страница 17: ... equipment described in this manual Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation Trademark Ethernet is a registered trademark of Xerox Corporation ...

Страница 18: ...CCU 790 790P UC CE 3 210 787 02 1 2007 Sony Corporation ...

Отзывы: