Self-Diagnostics
13
Page 2
NS Mode:
Setting for the ETHERNET connection mode
LEGACY: Connection mode for the REMOTE
connector (factory-setting)
BRIDGE: ETHERNET connection mode
MCS: ETHERNET connection mode
MCS Mode:
Setting of master or client for the Ethernet
connection of the multi-camera system
CLIENT: Client mode (This unit is placed under
control of the master device.)
CCU No.:
CCU number setting
Master IP Address:
IP address of the master device
Page 3
IP Addr:
IP address
NetMask:
Net mask
Def GW:
Default gateway
Self-diagnostics results of the CCU-
790/790P internal boards
For details on the internal boards, refer to the System
Manual.
DM board
CAM Video
: Status of the Y, R-Y, and B-Y signals of the
triax signal
Skin Gate
: Reception status of the Skin gate signal from
the camera
TRIAX Comp.
: Cable compensation of a triax cable
TRIAX Step
: Compensation step of the triax cable (step
indication in the circuit) (The cable length may not be
displayed correctly.)
Power
: DM board power supply status
TR board
Prompter
: Setting status of the prompter line
Tone
: Tone signal status
Incom
: Demodulating status of the intercom line
CHU Data
: Data reception status from the camera
Power
: TR board power supply status
BoardID
: ID number of the TR board
AT board
Reference:
Operation mode of the phase adjustment