4-6-14. CHU DATA Demodulation Adjustment
Adjustment category:
C
Notes:
.
Perform this adjustment together with the already
adjusted CA-590/590P.
.
Perform this adjustment only after replacing IC201 and/
or
1
LV201 (5.6M TUNE) on the TR-133B board.
Measuring instrument:
Oscilloscope
20 MHz BW Limit: ON
Input mode:
DC
Extended board:
TR-133B board
Measurement point:
TP201 (GND: E1)/TR-133B board
Adjustment point:
1
LV201 (5.6M TUNE)/TR-
133B board
Specification:
A =
+
0.50
±
0.02 V dc
4-6-15. CHU TONE Adjustment
Adjustment category:
C
Measuring instrument:
Oscilloscope (set to AC mode)
Extended board:
TR-133B board
Measurement point:
TP202 (GND: E1)/TR-133B
board
Adjustment point:
1
RV201 (TONE ADJ)/TR-
133B board
Adjustment procedure:
1.
Set the oscilloscope as follows.
.
HORIZ/DIV: 20 mS/DIV
.
VOLTS/DIV: 100 mV/DIV
.
Input mode: AC
2.
Turn slowly
1
RV201 clockwise
2
from the mechani-
cal center while watching the oscilloscope, and record
the wave starting position (a).
3.
Turn slowly
1
RV201 counterclockwise
3
while
watching the oscilloscope, and record the wave
starting position (b).
4
Set
1
RV201 to the center of (a) and (b).