![Sony CCU-590P Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/sony/ccu-590p/ccu-590p_maintenance-manual_392166070.webp)
CCU-590/P/V1(E)
4-6
CN902
E1
E2
E3
RV101
RV102
RV103
RV104
RV105
RV106
RV301
RV302
RV303
RV304
RV305
RV501
RV502
S301
S701
S702
S703
S704
S705
S706
S707
S708
S709
TP101
TP102
TP103
TP104
TP301
TP302
TP303
TP304
TP305
TP306
TP501
TP502
TP503
TP504
A
B
C
D
E
F
G
H
J
1
2
3
4
EN-156B BOARD (SIDE A)
[For NTSC]
[For PAL]
A
A
4-3-5. Y OUT Level Adjustment 1
Adjustment category:
A
Measuring instrument:
Waveform monitor
Extended board:
EN-156B board
Preparation:
.
BARS button/RM or RCP
→
“ON”
.
S701-4 (RGB-YCd)/EN-156B board
→
“ON (YCd)”
.
S702-1 (G/Y-SYNC)/EN-156B board
→
“ON”
.
S702-4 (SET UP)/EN-156B board
→
“ON” (UC) NTSC
.
S702-4 (SET UP)/EN-156B board
→
“OFF” (CE) PAL
Measurement point:
Y/G OUT terminal/CCU rear
panel
Adjustment procedure:
EN-156B board
Adjustment
Specification
point
Y level adjustment
1
RV106
A = 100
±
1 IRE (for NTSC)
A = 700
±
7 mV (for PAL)
4-3-6. Y OUT Level Adjustment 2
Adjustment category:
A
Preparation:
.
S702-4 (SET UP)/EN-156B board
→
“ON”
Measurement point:
Y/G OUT terminal/CCU rear
panel
Adjustment procedure:
EN-156B board
Adjustment
Specification
point
Y level adjustment
1
RV101
A = 100
±
1 IRE (for NTSC)
A = 700
±
7 mV (for PAL)
[For NTSC]
[For PAL]
A