CCU-590/P/V1(E)
4-1
Section 4
Electrical Alignment
4-1. Preparation
4-1-1. Equipment and Tools Used
Measuring instruments
.
Oscilloscope (Bandwidth: 300 MHz or more)
Tektronix 2465 or equivalent
.
Waveform monitor/Vectorscope
Tektronix 1750A or equivalent (for NTSC)
Tektronix 1751A or equivalent (for PAL)
.
Color monitor
Sony BVM-1911/2811 or equivalent (for NTSC)
Sony BVM-2011P/3011P or equivalent (for PAL)
.
Video signal generator
Tektronix TSG170A or equivalent (for NTSC)
Tektronix TSG271 or equivalent (for PAL)
.
Digital voltmeter
Advantest TR6845 or equivalent
.
Frequency counter
Advantest TR5821AK or equivalent
.
Audio generator
Tektronix SG5010 or equivalent
.
Spectrum analyzer
Advantest R3261C or equivalent
Related equipment
.
Video camera Sony BVP-E30/E30P
.
Camera adapter Sony CA-590/590P
.
Remote control unit RM-B750 or RCP-750/751
4-1-2. Tools
.
RF signal extension cable:
(Sony Part No.: 1-830-369-11)
.
Extension board (EX-854):
(Sony Part No.: A-8344-228-A)
4-1-3. Precautions for Adjustment
.
Turn the adjustment variable resistor
1
RV101 on the
AT-155B board fully clockwise.
.
Do not turn the following filters on the DM-140 board in
any case. Replace a defective filter with a new one.
No adjustment is required after replacement.
DM-140 board
FL102, FL302, FL601 FL602, FL701, FL801, FL901
.
Each adjustment category lists an item to be adjusted
during installation, periodic inspection or part replace-
ment.
A:
During installation
A and B:
During periodic inspection
C:
During part replacement
.
Abbreviations described in the following sections mean
as follows.
(CCU):
CCU-590/590P
(CCU rear panel):
CCU-590/590P rear panel
(RM or RCP):
RM-B750 or RCP-750/751