CCU-590/P/V1(E)
4-19
CN902
S101
S102
S103
S104
S105
S107
S108
TP101
TP102
TP103
TP104
E1
E2
E3
RV101
RV102
RV103
RV104
RV105
RV106
RV401
A
B
C
D
E
F
G
H
J
1
2
3
4
5
IV-57B BOARD (SIDE A)
4-5-10. Y BLACK Adjustment
Adjustment category:
A
Measuring instrument:
Waveform monitor
Extended board:
IV-57B board
Preparation:
.
BARS button/RM or RCP
→
“OFF”
.
Turn the IRIS control to close.
.
Turn the MASTER BLACK adjustment knob to
_
99.
Measurement point:
VBS 1 OUT terminal/CCU rear
panel
Adjustment point:
1
RV101 (Y BLK)/IV-57B
board
Specification:
A = 0
±
1 IRE (for NTSC)
A = 0
±
7 mV (for PAL)
Setting after adjustment
.
Push the STD button on RM or RCP.
4-5-11. R-Y/B-Y Black Balance Adjustment
Adjustment category:
A
Measuring instrument:
Vectorscope
Extended board:
IV-57B board
Preparation:
.
BARS button/RM or RCP
→
“OFF”
.
Turn the IRIS control to close.
.
Turn the MASTER BLACK adjustment knob to
_
99.
Measurement point:
VBS 1 OUT terminal/CCU rear
panel
Adjustment procedure:
.
Adjust
1
RV103 (R-Y BLK) and
1
RV102 (B-Y BLK)
on the IV-57B board so that the black-level brilliant
point comes to the center of vectorscope screen.
Setting after adjustment
.
GAIN switch/Vectorscope
→
75 % CAL
.
Push the STD button on RM or RCP.
A