![Sony CCU-550A Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/sony/ccu-550a/ccu-550a_operation-manual_400539029.webp)
13(E)
Specifications
General
Power consumption 100 - 240 V AC, 50/60 Hz,
maximum 1.8 A
Peak inrush current (1) Power ON, current probe
method: 20 A (240V)
(2) Hot switching inrush current,
measured in accordance with
European standard EN55103-1:
2 A (230V)
Cable length
Maximum 1,400 m (ø 14.5 mm)
Operating temperature
–10°C to +40°C (14°F to 104 °F)
Dimensions
200
×
124
×
350 mm
(8
×
5
×
13
7
/
8
in.) (w / h / d)
not including projecting parts
Mass
Approx. 7 kg (15 lb 7 oz) (when
the BKP-5972 and the BKP-5073
are installed)
Input signals
REFERENCE
BNC type (loopthrough)
VBS/BS, 1.0 Vp-p, 75 ohms
RET 1/2/3
1)
BNC type (1 each, loopthrough)
VBS, 1.0 Vp-p, 75 ohms,
PROMPTER
1)
BNC type (loopthrough)
1.0 Vp-p, 75 ohms
Output signals
SERIAL 1/2
2)
BNC type (1 each)
4:2:2 component serial digital
(270MB/s), 0.8 Vp-p, 75 ohms
VBS 1/2/3
BNC type (1 each)
VBS, 1.0 Vp-p, 75 ohms
Y/R-Y/B-Y video
3)
BNC type (1 each)
Y: 1.0 Vp-p, 75 ohms
R-Y/B-Y: U.S.A. and Canada:
700 mVp-p, 75 ohms
Europe: 525 mVp-p, 75 ohms
R/G/B video
3)
BNC type (1 each)
700 mVp-p, 75 ohms
PIX
BNC type (1)
1.0 Vp-p, 75 ohms
WF
BNC type (1)
NTSC: 714 mVp-p, 75 ohms
PAL: 700 mVp-p, 75 ohms
Encoded output: 1.0 Vp-p, 75 ohms
WF MODE
4-pin (1)
MIC OUTPUT
XLR, 3-pin
0 dBu/–20 dBu, balanced, 2
channels
Camera input/output signals
CAMERA
Triax (Kings type for the U.S.A.
and Canada, Fischer type for
Europe)
COAX
BNC type (1), 75 ohms
RCP/CNU REMOTE
8-pin, multiconnector
INTERCOM/TALLY/PGM
D-sub, 25-pin (1)
4W/RTS
TALLY: 24 V DC, TTL level or
contact selectable
MIC REMOTE
D-sub, 15-pin (1)
INCOM (on the front panel)
XLR, 5-pin (1)
Supplied accessories
Operation Manual (1)
Maintenance Manual Part 1 (1)
AC power cord (1)
AC power plug holder (1)
4-pin connector (1)
Number plate (1 set)
Optional accessories
Extension board (service parts)
SDI Output Board BKP-5972
CCU Control Panel BKP-5973
DC Power Unit BKP-5974
Rack Mount Adaptor RMM-301
Design and specifications are subject to change
without notice.
1) RET 3 and PROMPTER is switchable.
2) Available with the BKP-5972 is installed.
3) R/G/B/and Y/R-Y/B-Y is switchable.
..........................................................................................................................................................................................................
Содержание CCU-550A
Страница 16: ......
Страница 30: ...14 E Self Diagnostics ...