5-1
DSR-300/P(E)/V1
SECTION 5
TAPE PATH ALIGNMENT
5-1. GENERAL INFORMATION FOR TAPE PATH ALIGNMENT
5-1-1. Equipment and Tools Used
.
Oscilloscope (Tektronix 2445B or equivalent)
.
Guide adjustment driver (SONY Part No. J-6082-362-A)
.
Small adjustment mirror (SONY Part No. J-6080-710-A)
.
RF extension tool (SONY Part No. J-6442-350-A)
.
Alignment tape, XH2-1AST (for DSR-1/1P, SONY Part No. 8-967-999-02)
.
Alignment tape, XH5-1A (for DSR-1, SONY Part No. 8-967-999-21)
.
Alignment tape, XH5-1AP (for DSR-1P, SONY Part No. 8-967-999-25)
.
Blanking tape (commercially available tape, SONY PDVM-40ME or equvialent)
.
Three bond 1401B
5-1-2. Tape Guide Adjustment Driver
and Locking Screw
(1) When performing the height adjustment of each
tape guide, use the tape guide adjustment driver
as a service tool.
(2) Adjust the heights of TG-1, TG-2, TG-3, TG-5,
TG-7 and TG-8 guides, then apply a screw-
locking compound to the locking screw of the
upper flange of the tape guide.
SONY Part No.
Tape guide adjustment driver
J-6082-362-A
Three Bond 1401B
7-432-114-11
Precaution on applying a screw-locking
compound:
.
Do not apply a screw-locking compound to a face
which is in contact with tape.
Tape guide
adjustment driver
Guide shaft screw
Screw-locking
compound
Tape guide
upper flange
Tape guide