2-63
DSR-300/P(E)/V1
Note:
Even if Menu No. 600 is “on,” it will automatically go “oFF” when the power is turned OFF.
[||]
[||]
[||]
[||]
[||]
is the factory setting
MENU
No.
503
509
513
600
MENU
DESCRIPTION
CALENDAR
DISPLAYS
HUMID TIMER
OFF
BP BATTERY
PRESET
MAINTENANCE
MENU ON/OFF
SELECT
Buttons used: RESET
→
RESET (MENU SET) button, ADV.
→
ADVANCE button, MENU
→
MENU button, SHIFT
→
SHIFT button.
Basic Operations of Buttons
Button
Function
ADVANCE button
Changes the set value
Menu No.
+
(Increase)
SHIFT button
Moves between displayed digits
Menu No.
_
(Decrease)
RESET (MENU SET) button
Registers the set value
(Returns to the menu selection
mode)
Start the adjustment
MENU button
Returns to the state before the
menu mode
Interrupt the adjustment
BUTTON
USED
ADV.
RESET
ADV.
SHIFT
RESET
ADV.
DISPLAY WINDOW (LCD)
CONTENTS
Display window (LCD) date display switching (TC mode
switch 1/TC panel is the setting format of U-BIT during DATE/
TIME)
Std: According to internal DIP SW
(NTSC is UC/J, PAL is CE only)
J:
Year/month/day
UC: Month/day/year
CE: Date/month/year
Releases HUMID TIMER
When set to HUMID MODE OFF at factory setting Menu No.
402, HUMID ALARM is displayed to protect the tape, and
VTR stops operations only for a certain period of time when
set by the HUMID TIMER when condensation occurs.
However, when condensation is removed manually, the
HUMID TIMER can be released at the menu.
(For details on how to release the HUMID TIMER, refer to 2-
14.)
The BP battery preset voltage can be set within the 12.0 to
15.9 V range.
(Refer to 2-19. for how to replace.)
Sets the MAINTENANCE MENU (menu No. 601 to 755) ON/
OFF.
on:
MAINTENANCE MENU are displayed.
oFF: MAINTENANCE MENU are not displayed.
Std /UC/J/CE
on/ oFF