6
Redbox RB-DSD8 User Handbook
3. Rear Panel DIPSwitch Settings
Fig 3-1: RB-DSD8 Rear Panel DIPSwitches
Rear Panel DIPSwitches: Bank 1 SILENCE LEVEL AND DURATION
Silence Detect Interval Control (DIPSwitches 1-7, Bank 1)
DIPSwitch
1
2
3
4
5
6
7
Seconds
2
4
8
16 32 64 128
The silence detect interval DIPSwitches adjust the duration over which a silence is detected
before alarming and ranges from 2-254 seconds by combining raised (ON) DIPSwitches in 2
second intervals with 0 being all DIPSwitches down. The default value is set at 30 seconds
but can be changed using the serial port or ethernet. This time can also be overridden by a
remote GPI/O input that sets the unit to an override time that is set to 2mins 5 seconds.
Silence Detect Trigger Level (DIPSwitches 8-11, Bank 1)
DIPSwitch
8
9
10 11
Level dBFS
-3
-6
-12 -24
The trigger level DIPSwitches adjust the level below which silence detection occurs. This
level may be varied from -27dBFS to -84dBFS in 3db steps by raising different combinations
(to ON). Please note the range changes depending on the full scale settings. These
represent -15dBU to -60 dBU
Full Scale
Min
Max
12dBU
-27dBFS
-72dBFS
18dBU
-33dBFS
-78dBFS
24dBU
-39dBFS
-84dBFS
Stereo/Mono Switch (DIPSwitch 12, Bank 1)
The configuration of this defines whether you want to switch sources when left and/or
right channel of the incoming source go silent. When channels are linked the stereo mode
becomes multichannel mode and any single mono channel failure will cause the unit to
switch sources; likewise mono mode will require both channels to fail individually before
switching sources.