Rollixo RTS
Copyright © 2012 Somfy SAS. All rights reserved
21
EN
optical safety edge transmitter (osE)
Press the PROG SW4 button on the safety edge transmitter. Press it down
until the indicator light goes out (the indicator light is permanently lit while the
button is pressed).
The transmitter indicator light will illuminate:
• first green to provide information on the assembly configuration
•
then red to indicate any faults.
transmitter indicator light
status
Diagnostics
Repair / Actions
1 green flash
Operation without magnet (default)
Check that there are no magnets installed on the door runner.
2 green flashes
Operation with lower magnet only
Check for the presence of magnet(s) on the door runner.
Check that the safety edge transmitter and the magnet(s) are installed on the right-hand side
of the door.
Perform the installation with magnet procedure again.
3 green flashes
Operation with upper magnet only
4 green flashes
Operation with upper and lower magnets
Permanently red Faulty OSE transmitter
See table below to identify the fault.
OSE transmitter indicator light fixed red: transmitter faulty
Actions
transmitter indicator light status
Result/troubleshooting
Open the OSE
transmitter
housing.
Remove and refit
the battery
LED 1 and LED 2: flash green once then
flash orange for 1 to 30 seconds, then
flash green for 5 seconds.
The battery and the transmitter are operating correctly.
If the problem persists, replace the battery (part no. 1782078).
LED 1 and LED 2: flash orange for 1 to
2 minutes
The battery is low, replace it (part no. 1782078).
LED 1 and LED 2 remain off
The OSE transmitter is no longer operating and must be replaced (ref. 1781245). Follow the
instructions provided with the OSE transmitter then carry out commissioning as described on
page 9.
Open the OSE
transmitter
housing.
Press button SW2
until LED 1 lights
up permanently
red.
LED 1 and LED 2 remain off
LED 1 and LED 2 light up red briefly
Check that the rubber on the safety edge is not crushed and repeat the check.
Check the photoelectric sensor wiring and repeat the check.
If the problem persists, replace the optical cells by following the instructions provided with the
cells.
Photoelectric sensors:
- for a strip of 3 m max.: ref. 9016767
- for a strip of 7 m max.: ref. 9015560
LED 1 lights up green then LED 2 lights
up permanently green for 8 seconds.
The OSE transmitter and the photoelectric sensors are operating correctly.
If the problem persists, replace the battery (part no. 1782078).
Battery
GENERAL tEChNICAL
sPECIfICAtIoNs
Power supply
196-253 V 50-60 Hz
Electrical insulation
Category 1
Maximum motor output
Safety fuse
230 V - 1250 W
5 AT - 250 V
Somfy radio frequency
433.42 MHz
Number of storable remote controls
32
Operating temperature
-20°C/+60°C
Protection rating
IP 20
CoNNECtIoNs
Mains power supply cable
2 m - IEC sheet (phase-neutral-earth)
Integrated courtesy lighting
E14 - 25W max. - 230V
Safety inputs
3 inputs for: - Wired safety edge: optical, resistive
- Fall protection device
- Photoelectric cells
Self-test output for safety devices
For cells
Wired control input
NO dry contact - sequential operation
Orange light
24V - 4W max.
Alarm siren output
Yes
oPERAtIoN
Control buttons
Up-Stop-Down buttons in the control panel
Automatic closing mode
Yes
Downgraded operation mode control
Automatically activated when lowering if a fault is detected on a safety device
Maintenance assistance
Real time status with 5 indicator lights