EN
37
SETTINGS
Warning! To validate and take into account the new settings
for the Switch 1 of DIP1 and all the switches of DIP 2, press
the RESET button on the top of the electronic board.
SPECIAL OPERATION
Cf. page 10 of the User Manual
CLEARING REMOTE CONTROLS
Press the « RTS Prog » button inside the FREEROLL until the light blinks (7 s).
This clears all of the remote controls memorised.
Dip Switch Settings
Standard operating mode
DIP 1
Switch 1 ON
PEC self-check software on (always
used if cells connected)
Switch 1 OFF
PEC self-check software off
Switch 2 ON
Dead Man open
Switch 2 OFF
Push to Run open
Switch 3 ON
Dead Man Close
Switch 3 OFF
Push to Run Close
Switch 4 ON
Programming Mode
Switch 4 OFF
Normal Running Mode
DIP 2
Switch 1 ON
Anti-lift function disabled
Switch 1 OFF
Normal Running Mode
Switch 2 ON
Generator Mode Enabled (only with
optional generator)
Switch 2 OFF
Normal Running Mode
Switch 3 ON
Do not use
Switch 3 OFF
Normal Running Mode
Switch 4 ON
Do not use
Switch 4 OFF
Normal Running Mode
DIP 1
DIP 2
RESET