26
QUICK INSTALLATION GUIDE
Warning ! From Step 1 to Step 3, you must use a test lead to operate the rolling garage door.
Do not connect the FREEROLL control unit until the end-limits have been set.
1. Set Motor end-limits
Set the UP and DOWN end-limits of the RDO CSI motor with a test lead (not-provided).
Refer to the motor instruction guide.
2. Position the TOP and BOTTOM Magnets on the door guide
Warning ! Position the magnets, the Safety Edge Transmitter and the FREEROLL control unit
on the same side of the door
3. Door position
10 mm maxi.
Back of the
Safety Edge
Transmitter.
10 mm maxi.
Back of the
Safety Edge
Transmitter.
BOTTOM Magnet
BOTTOM Magnet
50 mm mini.
60 mm maxi.
TOP Magnet
50 mm mini.
60 mm maxi.
TOP Magnet
Place the back of the Safety Edge Transmitter against
the bottom slat of the door respecting the space of 10
mm maximum with the edge of the guide.
Warning! The Magnets are used to activate and
deactivate the safety edge.
They must be positioned as indicated and never
removed (autonomy and safety managements).
Fit the TOP Magnet: the door must be in the OPEN end-
limit position. Remove the backing strip and screw the
magnet on the guide respecting the distance (height) of
50 mm minimum and aligning with the edge of the guide.
Fit the BOTTOM Magnet: the door must be in the
CLOSED end-limit position. Remove the backing strip
and screw the magnet on the guide respecting the
alignment with the Safety Edge Transmitter.
ground
BOTTOM
Magnet
TOP
Magnet
Back of the
Safety Edge Transmitter
ground
ground
BOTTOM
Magnet
TOP
Magnet
Back of the
Safety Edge Transmitter
Move the door to a mid position.