GB
7
TECHNICAL SPECIFICATIONS
Basic technical specifications
Dexxo Pro 800
Dexxo Pro 1000
Mains supply
230 V 50 Hz
Power consumed when on standby
5 W
Max. power consumed
350 W (excluding remotely controlled lighting)
Traction force
800 N
1000 N
Use
20 cycles per day with a standard rail (tested for 36,500 cycles)
50 cycles per day with a high performance rail (tested for 90,000 cycles)
Number of channels that can be stored
32
Somfy radio frequency
433.42 MHz RTS
Integrated light
230 V / 40 W max. E14 socket
Remote controlled lighting
230 V / 500 W max. Class 2
Operating temperature
-20 °C / +60 °C
MAINTENANCE
Replacing the bulb in the light unit (Fig. 12)
[1] [2].
Remove the light cover
[3] [4].
Unscrew and replace the defective light bulb
[5] [6] [7].
Refit the light cover
Use a 230 V 40 W E14 socket light bulb
Checking the obstacle detection function
Every six months, check that the door reverses direction when an obstacle prevents the door from closing (at least 50 mm above floor level).
Checking the safety mechanisms (cells, pedestrian door contact, sensor bar)
Check correct operation every six months (refer to page 5).
Checking the back-up battery
To ensure optimum battery life, we recommend that the power to the motor is switched off and the door is operated for a number of cycles using
battery power (three times a year).
1
12
2
5048551A-GB 26/04/07 14:37 Page 7