background image

GB

2

GENERAL PRESENTATION

2

The world of Somfy

2

Support

2

SAFETY INSTRUCTIONS 3

Standards

3

Safety instructions

3

PRODUCT PRESENTATION 

3

Description 

3

OPERATION AND USE 

4

Normal operation

4

Special operation

5

TROUBLESHOOTING 6

PERIPHERALS 6

Description of the different peripherals available

6

MAINTENANCE 7

Replacing the bulb

7

Checking the obstacle detection function

7

Checking the safety mechanisms

7

Checking the back-up battery

7

TECHNICAL SPECIFICATIONS 7

NOTES 8

CONTENTS

Thank you for choosing a Somfy product. This product is designed and manufactured by Somfy in line with quality procedures that are ISO 9001
compliant.

The world of Somfy

Somfy develops, produces and sells automation systems for residential and commercial applications. Alarm systems, automatic blinds and shutters,

garage doors and gates - all Somfy products are designed to fulfill your needs in terms of safety, comfort and security.

At Somfy, the quest for quality is a continual process. Somfy has built its reputation on the quality of its products and is synonymous with innovation
and technological leadership worldwide.

Support

Getting to know you, listening, answering your needs, is all part of the Somfy approach.

Please contact your local Somfy retailer or installer for details on other Somfy products.

Internet: www.somfy.com

GENERAL PRESENTATION

5048551A-GB  26/04/07  14:37  Page 2

www.garagedoorsonline.co.uk

01926 463888

www.garagedoorsonline.co.uk

www.garagedoorsonline.co.uk

01926 463888

www.garagedoorsonline.co.uk

Содержание Dexxo Pro

Страница 1: ... in lighting operation 6 CONNECTING PERIPHERALS 6 Description of the various peripherals 6 Electrical connections for the various peripherals 6 SETUP 7 Setup general diagram 7 Definition of the different settings 7 SPECIAL OPERATION 8 CLEARING REMOTE CONTROLS AND ALL SETTINGS 8 Clearing remote controls 8 Resetting all settings 8 TROUBLESHOOTING 8 Operating codes displayed 8 Programming codes displ...

Страница 2: ...s used we recommend storing it close to the door Fix the label describing the manual release procedure close to the release mechanism Fix the warning labels describing the hazards of door motion close to any fixed control mechanisms installed and make sure that the labels are clearly visible to the user After installation make sure that the mechanism is correctly adjusted and that the motor drive ...

Страница 3: ...omplied with throughout the installation process Take off any personal jewellery bracelet chain or others during installation work During drilling and welding work always wear safety glasses and suitable protection Always use suitable tools Take care when handling the motor drive system Never connect the mains power supply or the battery back up system before completing the installation process Ne...

Страница 4: ...The stop positions can be set by positioning the door open or closed using the forced operation mode Fig 39 Fitting the chain retainer pads Fig 14 For chain rails only Position the chain retainer pad into the first hole in the rail after each travel stop Be sure to press the pad all the way down so that the positioning pin sticks out from the rail Make sure that the manual release cord is located ...

Страница 5: ...ning was correct the display will show C1 If the learning cycle was not completed correctly the display will show S0 or S1 The learning cycle can be run at any time when the trolley is engaged and the display shows S2 During the learning cycle If the door is moving pressing any button will stop the movement and interrupt the learning mode If the door is stopped pressing SET once will exit the lear...

Страница 6: ...Without warning before door movement P1 0 With a 2 s warning before door movement P1 1 Code keypad Fig 28 Pedestrian door safety kit Fig 29 When the pedestrian door contact is fitted it must be connected in place of the jumper normally fitted between terminals 5 and 6 in the terminal block If the pedestrian door contact is removed the jumper between terminals 5 and 6 in the terminal block must be ...

Страница 7: ... the remote control button will fully open the door P5 Closing speed 0 fast 1 standard 2 slow If this setting is changed it is essential to run the force measurement sequence at the end of the installation procedure refer to the Installation Checklist for domestic doors in residential areas or install a sensor bar P6 Partially open position Storing the position as illustrated in Fig 35 P7 Closure ...

Страница 8: ...ed during safety mechanism self tests Cb Permanent hardwired control Indicates that the permanent hardwired control input is activated contact closed Commands from radio remote control units are inhibited Cd Working from back up battery Waiting for a command SPECIAL OPERATION Refer to the User s Manual page 5 Programming example setting the P7 closure approach speed Fig 34 Setting up a long soft s...

Страница 9: ...le counter with obstacle detection thousands U5 Number of control channels memorised d0 to d9 Log of the last ten faults dd Clears the fault log press OK for 7 s Fig 33 Error and failure codes displayed Accessing stored data To access stored data select the Ud setting then press OK as shown in Fig 33 Programming codes displayed Code Description Comments S0 Awaiting setting Motor operating directio...

Страница 10: ... 000 cycles Min height under the lintel 35 mm Overall length With a 2 9M rail 3 240 mm 3 090 mm if the motor head is mounted with a 90 offset With a 3 5M rail 3 740 mm 3 590 mm if the motor head is mounted with a 90 offset Weight Motor head 6 8 kg Rail 5 6 to 10 kg depending on the type of rail Opening speed 18 cm s max Number of channels that can be stored 32 Somfy radio frequency 433 42 MHz RTS ...

Страница 11: ... Dexxo Pro 800 1000 RTS User Manual 5048551A 5048551A GB 26 04 07 14 37 Page 11 www garagedoorsonline co uk 01926 463888 www garagedoorsonline co uk www garagedoorsonline co uk 01926 463888 www garagedoorsonline co uk ...

Страница 12: ...mfy Somfy develops produces and sells automation systems for residential and commercial applications Alarm systems automatic blinds and shutters garage doors and gates all Somfy products are designed to fulfill your needs in terms of safety comfort and security At Somfy the quest for quality is a continual process Somfy has built its reputation on the quality of its products and is synonymous with...

Страница 13: ...r future reference Safety instructions Every month test that the motor drive unit reverses its motion when it encounters an obstacle that is at least 50 mm from ground level If this is not the case call your installation specialist Always be very careful when using the manual release cord for a manually operated door may fall quickly due to weak or broken springs or if it is badly balanced Before ...

Страница 14: ...manual release mechanism should be easily accessible and located no more than 1 80 metres above floor level 1 Disengaging the motor drive mechanism Pull on the manual release cord until the door drive mechanism is disengaged 2 Manually moving the door This is possible as long as the door drive mechanism is disengaged 3 Reengaging the motor drive mechanism Move the door manually until the drive mec...

Страница 15: ...strated in Fig 10 Partial opening operation If this option is selected A short press on the remote control button will partially open the door A long press on the remote control button will fully open the door The partially open position will only operate from the closed position Automatic closure mode operation The door is automatically closed after a time delay set at the time of installation An...

Страница 16: ... the garage door is the only access point into the garage 11 Door locking kit A system to reinforce door locking PERIPHERALS A number of peripherals are available 1 11 1 C Co od de e Description Comments C1 Waiting for a command C2 Door opening C3 Waiting for the door to close C4 Door closing C5 Obstacle detection Indicates that the door encountered an obstacle The display is maintained for 30 s a...

Страница 17: ...ig 12 1 2 Remove the light cover 3 4 Unscrew and replace the defective light bulb 5 6 7 Refit the light cover Use a 230 V 40 W E14 socket light bulb Checking the obstacle detection function Every six months check that the door reverses direction when an obstacle prevents the door from closing at least 50 mm above floor level Checking the safety mechanisms cells pedestrian door contact sensor bar C...

Страница 18: ...NOTES 8 GB 5048551A GB 26 04 07 14 37 Page 8 www garagedoorsonline co uk 01926 463888 www garagedoorsonline co uk www garagedoorsonline co uk 01926 463888 www garagedoorsonline co uk ...

Отзывы: