LINE VOLTAGE POWER SUPPLY OPTIONS

AC RS485 TUBULAR MOTORS

GLYDEA ULTRA WITH RS485 MODULE

DMI is powered by the motor using Grey Motor Data Cable

DMI is powered by the low voltage power supply 

options below 

(Requires cable #9014794 for power input)

LOW VOLTAGE POWER SUPPLY OPTIONS

TRANSFORMER OPTION

24V DC 1.67A Wall Mount Power Supply

#1822209

POWER DISTRIBUTION ENCLOSURE KITS

Max. distance of 150ft. with 16 AWG wire

5 Motor 

#1870196

10 Motor 

#1870192

15 Motor 

#1870197

20 Motor 

#1870198

II. INSTALLATION

M O U N T I N G

4 of 10

This device is powered by a line voltage AC SDN RS485 motor or a 24V DC power supply.

The Control4 to Digital Motor Interface utilizes mounting tabs with screw holes for installation. 

There is a single RJ45 port on the DMI which provides the connection to the SDN motor or adaptor cable.

The DMI is powered by a line voltage SDN RS485 motor using a Grey Motor Data Cable or low voltage power 

supplies including a plug-in transformer or power distribution enclosure kit. 

ELECTRICAL SPECIFICATION

Voltage Input

Requires regulated 24V DC or AC SDN Motor power output

Voltage Output

Regulated 24V DC, passed through from the Input Voltage

Power Connectors

2 pin JST, 2 mm pitch (Same for input & output)

Power Consumption

50mA @ 24V DC

P O W E R

Содержание CONTROL4

Страница 1: ...PROGRAMMING GUIDE TO DIGITALMOTORINTERFACE DMI ...

Страница 2: ...G TO SYSTEM FOR OPERATION III SET UP 6 ADD BLIND DEVICE TO PROJECT INDENTIFY DEVICE SET BLIND DEVICE PROPERTIES APPENDIX 9 A AVAILABLE COMMANDS ACTIONS TABLE OF CONTENTS V E R S I O N 1 0 J U N E 2 0 2 2 P r e p a r e d b y P R O J E C T S E R V I C E S CONTROL4TODIGITALMOTORINTERFACE DMI PROGRAMMING GUIDE 2 of 10 ...

Страница 3: ... D A P T O R C A B L E When installing the Digital Motor Interface DMI with DC motors the Data Power Adaptor Cable Ref 9027112 sold separately is required for proper installation Using the DMI with AC SDN RS485 motors requires the Somfy Grey Motor Data Cables sold separately 3 of 10 Power Output Output port for 24V DC power to motor SDN Port Connect to motor or Data Power Cable Push Button Leaving...

Страница 4: ...s device is powered by a line voltage AC SDN RS485 motor or a 24V DC power supply The Control4 to Digital Motor Interface utilizes mounting tabs with screw holes for installation There is a single RJ45 port on the DMI which provides the connection to the SDN motor or adaptor cable The DMI is powered by a line voltage SDN RS485 motor using a Grey Motor Data Cable or low voltage power supplies inclu...

Страница 5: ... of 10 W I R I N G T O S Y S T E M F O R O P E R A T I O N W I T H A C R S 4 8 5 M O T O R W I T H G L Y D E A U L T R A M O T O R W I T H D C R S 4 8 5 M O T O R NOTE Irismo 35 Mini DC is not supported ...

Страница 6: ...ocumentation tab A Somfy Control4 to Digital Motor Interface driver is required for each DMI installed 1 In the Composer System Design view Project tree SELECT a Room in which a device is to be added 2 In the Items pane SELECT the Search tab 3 In the Manufacturer dropdown list SELECT Somfy 4 SELECT the Somfy Control4 to Digital Motor Interface certified driver 5 DOUBLE or RIGHT CLICK the driver to...

Страница 7: ...ally in Identify mode upon power up For systems with multiple units it is recommended to power up and identify the units one at a time 2 In the Composer Connections view Network tab SELECT Zigbee Network 3 In the Zigbee Network Connections Device list SELECT the DMI to be identified 4 SELECT Identify 5 PRESS HOLD the Push Button on the DMI for seven seconds 6 Once the Address field populates the n...

Страница 8: ...product in the dropdown 3 SELECT the appropriate Blind Movement for the product in the dropdown 4 DOUBLE CLICK the DMI to test each button operation If the SDN motor operates in the opposite direction SELECT Reversed in the Blind Direction dropdown See Appendix A of this guide for a list of Digital Motor Interface available commands and actions In the View Modify Level Binding set Control4 keypad ...

Страница 9: ...E U P D A T E APPENDIX 9 of 10 DIGITAL MOTOR INTERFACE COMMANDS Close Moves blind to the fully closed position Open Moves blind to the fully open position Stop Stops blind when moving Toggle Sequence controls blind close stop open Target Level Moves blind to a percent openness 0 100 ...

Страница 10: ...tion systems are easily integrated with security HVAC and lighting systems providing total home or building automation FOR QUESTIONS OR ASSISTANCE PLEASE CONTACT TECHNICAL SUPPORT 800 22 SOMFY 76639 technicalsupport_us somfy com SOMFY SYSTEMS INC SOMFY NORTH AMERICAN HEADQUARTERS 121 Herrod Blvd Dayton NJ 08810 P 609 395 1300 F 609 395 1776 FLORIDA 1200 SW 35th Ave Boynton Beach FL 33426 F 561 995...

Отзывы: