Power Input

Input port for 24V DC 

power from power supply

I. OVERVIEW

SDN Motor limits must be set prior to installing Digital Motor Interface

NOTE: Refer to the respective motor instructions on how to set the limits

All connections must be properly made according to the wiring diagrams on the product instructions

Fully commissioned Control4 system

Control4 Composer Software OS 2.9.0 or higher
Somfy Control4 to Digital Motor Interface driver

The Control4 to Digital Motor Interface (DMI) receives and sends bi-directional commands and feedback 

connected between Somfy wired SDN RS485 motors and a Control4 Zigbee system as a wireless end node. 

It receives Control4 Zigbee transmissions and converts them to motor control commands for Somfy’s line of 

line voltage (AC) and low voltage (DC) SDN RS485 motors.

S Y S T E M   R E Q U I R E M E N T S

C O N N E C T I O N S   &   I N D I C A T O R S

M O T O R   A D A P T O R   C A B L E

When installing the Digital Motor Interface (DMI) with DC motors, the Data & Power Adaptor Cable (Ref # 9027112, sold separately) is required 

for proper installation. Using the DMI with AC SDN RS485 motors requires the Somfy Grey Motor Data Cables (sold separately).

3 of 10

Power Output

Output port for 24V DC 

power to motor

SDN Port

Connect to motor or 

Data & Power Cable

Push Button

Leaving the Zigbee 

network, restart identify 

& manual operation

LED BEHAVIOR

:

(LEFT)

OFF

NO POWER TO DEVICE

GREEN

POWER TO DEVICE

LED BEHAVIOR

:

(RIGHT)

ORANGE

>

GREEN

(Solid>Flashing)

SDN MOTOR ACTIVITY

GREEN

(Flashing)

NO MOTOR FEEDBACK

ORANGE

(Flashing)

INCLUSION MODE

ORANGE

(Solid)

CONNECTED TO ZIGBEE NETWORK

Control4 Digital Motor 

Interface Connection

Connect to SDN Port on the 

Digital Motor Interface 

Power Supply 

Connection

Connect to the power 

supply to provide power  

Digital Motor 

Connection

Connect to SDN RS485 

Digital Motor Cable(s) 

Each DMI is limited to one SDN RS485 motor connection

During power-up, the RIGHT 

LED will flash indicating the 

firmware version. 

Refer to product instructions for 

more detail.

Содержание CONTROL4

Страница 1: ...PROGRAMMING GUIDE TO DIGITALMOTORINTERFACE DMI ...

Страница 2: ...G TO SYSTEM FOR OPERATION III SET UP 6 ADD BLIND DEVICE TO PROJECT INDENTIFY DEVICE SET BLIND DEVICE PROPERTIES APPENDIX 9 A AVAILABLE COMMANDS ACTIONS TABLE OF CONTENTS V E R S I O N 1 0 J U N E 2 0 2 2 P r e p a r e d b y P R O J E C T S E R V I C E S CONTROL4TODIGITALMOTORINTERFACE DMI PROGRAMMING GUIDE 2 of 10 ...

Страница 3: ... D A P T O R C A B L E When installing the Digital Motor Interface DMI with DC motors the Data Power Adaptor Cable Ref 9027112 sold separately is required for proper installation Using the DMI with AC SDN RS485 motors requires the Somfy Grey Motor Data Cables sold separately 3 of 10 Power Output Output port for 24V DC power to motor SDN Port Connect to motor or Data Power Cable Push Button Leaving...

Страница 4: ...s device is powered by a line voltage AC SDN RS485 motor or a 24V DC power supply The Control4 to Digital Motor Interface utilizes mounting tabs with screw holes for installation There is a single RJ45 port on the DMI which provides the connection to the SDN motor or adaptor cable The DMI is powered by a line voltage SDN RS485 motor using a Grey Motor Data Cable or low voltage power supplies inclu...

Страница 5: ... of 10 W I R I N G T O S Y S T E M F O R O P E R A T I O N W I T H A C R S 4 8 5 M O T O R W I T H G L Y D E A U L T R A M O T O R W I T H D C R S 4 8 5 M O T O R NOTE Irismo 35 Mini DC is not supported ...

Страница 6: ...ocumentation tab A Somfy Control4 to Digital Motor Interface driver is required for each DMI installed 1 In the Composer System Design view Project tree SELECT a Room in which a device is to be added 2 In the Items pane SELECT the Search tab 3 In the Manufacturer dropdown list SELECT Somfy 4 SELECT the Somfy Control4 to Digital Motor Interface certified driver 5 DOUBLE or RIGHT CLICK the driver to...

Страница 7: ...ally in Identify mode upon power up For systems with multiple units it is recommended to power up and identify the units one at a time 2 In the Composer Connections view Network tab SELECT Zigbee Network 3 In the Zigbee Network Connections Device list SELECT the DMI to be identified 4 SELECT Identify 5 PRESS HOLD the Push Button on the DMI for seven seconds 6 Once the Address field populates the n...

Страница 8: ...product in the dropdown 3 SELECT the appropriate Blind Movement for the product in the dropdown 4 DOUBLE CLICK the DMI to test each button operation If the SDN motor operates in the opposite direction SELECT Reversed in the Blind Direction dropdown See Appendix A of this guide for a list of Digital Motor Interface available commands and actions In the View Modify Level Binding set Control4 keypad ...

Страница 9: ...E U P D A T E APPENDIX 9 of 10 DIGITAL MOTOR INTERFACE COMMANDS Close Moves blind to the fully closed position Open Moves blind to the fully open position Stop Stops blind when moving Toggle Sequence controls blind close stop open Target Level Moves blind to a percent openness 0 100 ...

Страница 10: ...tion systems are easily integrated with security HVAC and lighting systems providing total home or building automation FOR QUESTIONS OR ASSISTANCE PLEASE CONTACT TECHNICAL SUPPORT 800 22 SOMFY 76639 technicalsupport_us somfy com SOMFY SYSTEMS INC SOMFY NORTH AMERICAN HEADQUARTERS 121 Herrod Blvd Dayton NJ 08810 P 609 395 1300 F 609 395 1776 FLORIDA 1200 SW 35th Ave Boynton Beach FL 33426 F 561 995...

Отзывы: