![background image](http://html1.mh-extra.com/html/somfy/axovia-220b/axovia-220b_installation-manual_1317742008.webp)
6
PrEPArATiON ANd drilliNG Of PillArS
For the indicated values, the gate leaves and their hinge pins are taken to
be on the same axis.
If the hinge pins are offset, the maximum opening angle values will be
reduced.
[1].
Measure dimension A.
[2].
Select dimension B in the table according to the required opening
angle.
A (mm)
α max. (°)
B (mm)
0
120
205
110
160
105
150
50
100
150
100
95
150
150
90
150
200
90
150
250
90
150
[3].
Trace axis AM on the pillar copying dimension B on the pillar.
65 mm
[6].
Trace horizontal line AH in the middle of the reinforcement, perpendicular
to the rotational axis of the gate.
If the gate has no reinforcements, place the motors approximately
1/3 of the way up the gate leaves from the bottom.
Extend this line on the pillar until it intersects with AM.
[7].
Place the template where the 2 lines intersect and drill.
[4].
Check that dimension D is greater than or equal to 435 mm.
There must be no obstacles to impede the movement of the arm in this
area.
[5].
Check that dimension L is between 800 mm and 2000 mm.
If L < 1250, the installation of a set of photoelectric cells is essential.
5101723A_Axovia-220B.indd 6
10/05/2011 15:38:19
Содержание Axovia-220B
Страница 1: ...Installation guide 5101723A www somfy fr Axovia 220B 5101723A_Axovia 220B indd 1 10 05 2011 15 37 50...
Страница 2: ...5101723A_Axovia 220B indd 2 10 05 2011 15 37 50...
Страница 17: ...15 Orange light Key lock Interphone Exterior aerial 5 mm 15 mm 5101723A_Axovia 220B indd 15 10 05 2011 15 38 36...
Страница 20: ...18 5101723A_Axovia 220B indd 18 10 05 2011 15 38 40...