background image

2

This Somfy product must be installed by a professional motorisation and home automation installer, for whom this guide is intended. 

This  product,  installed  in  accordance  with  this  guide,  complies  with  EN  12453  and  EN  13241-1  standards.  It  is  the  installer's  responsibility  to  ensure 

that the automatic installation and its operation are compliant with the standards in force.

The  use  of  any  safety  components  not  approved  by  Somfy  remains  the  sole  responsibility  of  the  installer.  The  selected  safety  accessories  for  the 

installation must comply with the current standards and regulations in force in the country in which the product is being installed.
Moreover, the installer must comply with current standards and legislation in the country in which the product is being installed, and inform his customers of the 

conditions for use and maintenance for the product.
Any use outside the sphere of application specified by Somfy is forbidden. This invalidates the warranty and discharges Somfy of all liability, as does any failure 

to comply with the instructions given herein.
Hereby, Somfy declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A declaration of 

conformity is available on the website at www.somfy.com/ce (AXOVIA 220B), usable in UE, CH and NO.

GENErAl iNfOrmATiON

SAfETy

Safety instructions

Important safety instructions. Follow all the instructions as incorrect installation can lead to serious injury. 
This device is not designed to be used by persons (including children) whose physical, sensory or mental capacity is impaired, or persons with little experience or 

knowledge, unless they are under supervision or have received instructions on using the device by a person responsible for their safety. 

Check that the temperature range marked on the motors is suited to the location where the motors are to be installed.
Before installing the motor, ensure that the driven part is in good mechanical condition, that it is correctly balanced and that it opens and closes correctly.
The motor cannot be used with a driven part incorporating a small gate (unless the motor is inhibited when the small gate is opened).

Ensure that there are no danger zones (risk of crushing, cutting, trapping) between the gate and the surrounding fixed elements caused by the opening movement 

of the gate.
Watch the gate while it is moving.
Place the fixed control devices and remote controls out of the reach of children. 
Any switch without a locking device must be installed in direct view of the gate and away from any mobile parts. Unless it is key-operated, it must be installed at 

a minimum height of 1.5 m and must not be accessible to the public.
During installation of the motorisation:

Remove any jewellery (bracelets, chains, etc.).

 

-

For drilling and welding operations, wear special glasses and sufficient protection.

 

-

Use the appropriate tools.

 

-

Do not connect to the power source until installation is complete.

 

-

Be careful when handling the motorisation system to prevent any risk of injury.

 

-

After installation, ensure that the mechanism is correctly adjusted and that the protection system and any manual release mechanism operate correctly.
Regularly check the condition of the gate. Gates in poor condition must be repaired, reinforced or even replaced. Check that the various motorisation component's 

screws and fittings are correctly tightened. 

Before carrying out work on the installation, switch off the power supply.

In order to operate, the motor must be supplied with 230 V -50 Hz. The electric line should:
- solely be used for the motor,
- have a minimum cross section of 1.5 mm²,
- be equipped with protection (10 A fuse or breaker) and a differential device (30 mA),

- be equipped with an all-pole disconnection device,
- be installed in accordance with the current electrical safety standards.
It is recommended that the installation be fitted with a lightning conductor (in compliance with standard NF C 61740, maximum residual voltage 2 kV).
All 230 V lighting connected to the “zone lighting” output must be connected to earth or be of the double isolation type.

5101723A_Axovia-220B.indd   2

10/05/2011   15:37:50

Содержание Axovia-220B

Страница 1: ...Installation guide 5101723A www somfy fr Axovia 220B 5101723A_Axovia 220B indd 1 10 05 2011 15 37 50...

Страница 2: ...5101723A_Axovia 220B indd 2 10 05 2011 15 37 50...

Страница 3: ..._________________________________ 10 Cable guide fitting 10 Connection of the two motors 10 Aerial wiring 10 Mains cable connection 10 Locking the arms 11 Quick commissioning__________________________...

Страница 4: ...anical condition that it is correctly balanced and that it opens and closes correctly The motor cannot be used with a driven part incorporating a small gate unless the motor is inhibited when the smal...

Страница 5: ...x 4 22 End stop cover x 4 8 Information card x 1 23 End stop bolt x 6 9 Enclosure cover x 2 24 End stop upper part lower part x 2 10 O ring x 2 25 Motor arm gate leaf arm short shaft x 2 11 Cover bolt...

Страница 6: ...otection rating IP 44 Integrated radio receiver Yes Number of storable remote controls 16 Motor feed outputs 24 V DC Power per motor 120 W Output for orange light Flashing 24 V 15 W Area lighting outp...

Страница 7: ...hat its structure is suitable for automatic control and that it conforms to the relevant standards The gate must remain horizontal throughout its travel and must open and close manually with ease Ensu...

Страница 8: ...lar 65 mm 6 Trace horizontal line AH in the middle of the reinforcement perpendicular to the rotational axis of the gate If the gate has no reinforcements place the motors approximately 1 3 of the way...

Страница 9: ...a permanent marker na me tel name tel 3 Attach the motor checking the level 4 Assemble the motor arm to the motor with an HM 10x40 bolt 19 the gate leaf arm to the motor arm with the short shaft 24 N...

Страница 10: ...ust be lined up with the motor arm arrow Ensure the markers on the motor arm and the gate arm are lined up to ensure the gate is properly closed and can withstand strong winds or external forces 7 Mar...

Страница 11: ...the motor arm shoulder 5 Tighten the end stop with a long Allen key for greater torque when tightening the end stop bolts 16 Nm 6 Install the end stop covers screw the lower cover holding the shaft wh...

Страница 12: ...the motor before refitting the cover M1 est gauche OU M1 est droite If M1 is to the left and M2 to the right If M1 is to the right and M2 to the left connect the wire of to terminal connect the wire...

Страница 13: ...11 Locking the arms 1 Close the two gate leaves and lock the arms by pressing them 2 Turn the motor locking handles to the locked position 5101723A_Axovia 220B indd 11 10 05 2011 15 38 31...

Страница 14: ...mming the travel Auto programming the gate s travel is essential when commissioning the motor The gate must be closed before auto programming is started and at least one remote control must have been...

Страница 15: ...emote control button will lead to the following movements Open Stop Close Stop Open etc Automatic closure mode pressing the programmed button of the remote control will cause the gate to open The gate...

Страница 16: ...DC 0 V C NCNO 1 2 3 4 5 1 2 24 V AC DC 0 V CR1 CE1 1 2 24 V AC DC 0 V CE2 24 V AC DC 0 V C NCNO 1 2 3 4 5 CR2 2 10 m 40 cm max 20 cm TC Transmitter cell RC Receiver cell 24 V AC DC 0 V C NCNO 1 2 3 4...

Страница 17: ...15 Orange light Key lock Interphone Exterior aerial 5 mm 15 mm 5101723A_Axovia 220B indd 15 10 05 2011 15 38 36...

Страница 18: ...ended you have a manual unlocking system fitted ref 2400487 This will make it possible to enter the property and disengage the motors Area lighting Area lighting comes on with the motor and goes out 2...

Страница 19: ...ted on the motor output Rewire the motors to eliminate the short circuit The electronics are overheating wait 5 minutes before sending a new command The transmitter range is reduced Check that the pos...

Страница 20: ...18 5101723A_Axovia 220B indd 18 10 05 2011 15 38 40...

Страница 21: ...2 Safety instructions relating to operation 2 Use and operation_ _____________________________________________________ 3 Default operation in sequential mode 3 Operation in Automatic Closure mode 3 Sp...

Страница 22: ...l ensure that the safety requirements relating to property persons and the aforementioned standards are met Failure to comply with these instructions absolves Somfy of any liability resulting from dam...

Страница 23: ...se automatically after a delay time that was defined when activating the Automatic Closure mode It is possible to keep the gate in the open position by briefly pressing on the programmed button on the...

Страница 24: ...cycling Nous nous r servons le droit tout moment dans un souci constant d volution et d am lioration de nos mod les de leur apporter toutes modifications que nous jugerons utiles SOMFY SOMFY SAS capit...

Отзывы: