background image

The programming screen should now look like this: 

The first step in programming is to locate the node id. The 

8 digit ID located on the top of the motor controller, illustrated right. The last 6 digits of this 
is the MoCo base address in decimal. Note, communication must be done with the hexadecimal 
conversion of this address. To find the hexadecimal equivalent open the calculator on your pc. 
Choose view and make sure calculator is set to scientific (Figure 1). With the decimal check box 
selected enter in the last 6 digits of the ID located on the motor controller. To obtain the 
hexadecimal (hex) equivalent simply select the “hex” check mark and the ID will now be displayed 
in hex (Figure 2). 

 

 

Note, the ID displayed in Figure 2 has 5 digits instead of 6. Zero’s are not displayed in the first digit location. When 
entering this ID into the programming software, enter 06DA6B.

Motor Controller Addressing: 

Figure 1

Figure 2

Содержание animeo

Страница 1: ...any of the methods below RTS control Allows control via any Somfy RTS transmitter or RTS interface IR control Allows control via the Somfy 8 channel IR transmitter IR and RTS modules sold separately Dry contact Manually operate motors through a low voltage switch Main Power 24V DC Next MoCo Master Switch Dry Contact Input Master control to next MoCo Individual Switch dry contact control RS 485 in ...

Страница 2: ...es associated with the switch input which is being tested Note It is highly recommended to disconnect power prior to changing any wire configuration After the controllers have been properly mounted wired and motor directions tested refer to page 13 of the Animeo IB Motor Controller instruction booklet provided to configure the controller to the desired end product Note Failure to set the correct e...

Страница 3: ...lent open the calculator on your pc Choose view and make sure calculator is set to scientific Figure 1 With the decimal check box selected enter in the last 6 digits of the ID located on the motor controller To obtain the hexadecimal hex equivalent simply select the hex check mark and the ID will now be displayed in hex Figure 2 Note the ID displayed in Figure 2 has 5 digits instead of 6 Zero s ar...

Страница 4: ...and try again Explanation of Base Address and Individual Motor Addresses Take note in the command box top right there is one sent command and four receive commands Bytes 4 6 are the individual motor addresses The breakdown of theseaddresses are as follows 06DA6B Base Address master control of all 4 motor controller outputs 06DA6C Motor 1 Address 06DA6D Motor 2 Address 06DA6E Motor 3 Address 06DA6F...

Страница 5: ...he channel 2 is selected under MoCo channels and follow the same process To read an address choose the group address from the drop down menu and click the Get button The group address should appear in the text box directly to the right Node Label This field allows the programmer to assign up to a 32 digit label to the associated channel This could indicate a room number or office number Lock Statu...

Страница 6: ... allows the programmer to set the run times of each shade tilt and speed tilt if applicable Backlash setting enables venetian blinds to travel to the lower limit and reverse slats so that slats are horizontal For a run time of 30 seconds enter 300 For a run time of 16 seconds enter 160 Run time Tilt Only used for venetian blinds Enter the tilt time from slats close to close Speed Move and Speed Ti...

Страница 7: ...RS 232 or RS 485 capabilities RS 232 systems will require and RS 232 to RS 485 adaptor When integrating with third party systems it may be necessary to generate the hexadecimal command strings to input into the master controller The Command String Calculator can be found on the Somfy website www somfysystems com Click OEMs Fabricators Dealers Click here to go to the Trade Configuration software Ch...

Страница 8: ...am intermediate positions if necessary Accessories RTS Module 1860105 IR Module 1860098 IP Interface 1810850 Programmable Switch 3 button 1810827 Programmable Switch 6 button 1810828 USB to RS 485 convertor 9015260 RS 485 Repeater 1810816 Animeo Decora Single Switch 1800432 White Animeo Decora Single Switch 1800064 Ivory Animeo Decora Dual Switch 1800074 White Animeo Decora Dual Switch 1800075 Ivo...