MoCo Positioning:
Motor Position
sends channels to an Intermediate
Positions (IP).
Control:
allows manual up, stop, down
control of the selected channel or
group.
Motor IP:
Set or read intermediate
positions.
Key Modes:
Set the motor controller
end product.
Channel Links:
Set the switch input
control options.
Realign and Set to Default not used.
Not Implemented MoCo functions and
Raw Data not applicable.
MoCo Orders:
MoCo AC/DC, this
sections allows the programmer to
set the run times of each shade, tilt
and speed tilt if applicable.
Backlash
setting enables venetian
blinds to travel to the lower limit and
reverse slats so that slats are
horizontal.
For a
run time
of 30 seconds, enter
300. For a
run time
of 16 seconds,
enter 160.
Run time Tilt.
Only used for venetian
blinds. Enter the tilt time from slats
close to close.
Speed Move and Speed Tilt not
applicable on AC motors.
The following fields are not
applicable: MoCo DCE, DC Mode
Used, End Limit Switch Used, Slat
Shake Use, Tension Release Use,
and Reference Count.
Local Enabled
enables or disables the
use of local switching.