R
2
D
3
Data Capture Card
Installation and Operation
8-3
R2D3-ASSY-0327 (RJ-45 Connectors)
R2D3-ASSY-0427 (RJ-45 Connectors)
Signal Input
Signal Interface:
G.703, 2,048 kbits/s
Pulse shape:
As ITU-T G.703 pulse mask
Line code:
HDB3
Data type:
framed to ITU G.704
or
unframed
Input impedance 1:
120
Ω
balanced - default
(selectable
40
k
Ω
/ 75
Ω
)
Input sensitivity: -13.6dB
Input amplitude:
Nominal:
±3.00 V into 120
Ω
Maximum:
±5
V
Minimum:
±500
mV
Loss of signal threshold:
300 mV
Data decision threshold:
43% to 57% peak
Pulse width:
230 ns to 260 ns
Input jitter tolerance:
1200 UI at 10 kHz
14 UI at 750 Hz
0.4 UI at 10 kHz – 100 kHz
Signal Output
Signal Interface:
ITU G.703, 2,048 kbits/s
Line code:
HDB3
Output impedance:
120
Ω
balanced - default
(selectable
75
Ω
)
Output amplitude:
±3.00 V ±10% V into 120
Ω
Pulse width:
244 ±20 ns (at mid level)
Pulse-to-pulse jitter:
<100ns using internal clock and
<32ns using clock recovered from
an external 2,048kbits/s signal
1
When using high-impedance (40 k
Ω
) connections, the
recommended maximum cable length is 2 metres. For greater
distances, SomerData recommends using a SomerData
Splitter/Buffer
.
Содержание R2D3-ASSY-0130
Страница 2: ...R2D3 Data Capture Card This page intentionally blank ...
Страница 4: ...R2D3 Data Capture Card Installation and Operation This page intentionally blank ...
Страница 8: ...R2D3 Data Capture Card Installation and Operation This page intentionally blank ...
Страница 22: ...R2D3 Data Capture Card Installation and Operation 2 8 Data Flow Block Diagram ...
Страница 25: ...R2D3 Data Capture Card Installation and Operation 3 3 G 703 Pulse Mask ...
Страница 52: ...R2D3 Data Capture Card This page intentionally blank Installation and Operation 6 4 ...
Страница 60: ...R2D3 Data Capture Card Installation and Operation 7 8 This page intentionally blank ...
Страница 72: ...R2D3 Data Capture Card Installation and Operation 9 6 This page intentionally blank ...