R
2
D
3
Data Capture Card
Interface Adapter Configuration
The Interface Adapter is pre-set to work in most
applications without additional configuration.
The only user-configurable settings are shield connection
links between the 75
Ω
and 120
Ω
interfaces as shown in
the diagram below.
120
Ω
RJ-45 Connector
8
7
6
5
4
3
2
Installation and Operation
3-8
In the default configuration, the shield connections are
closed when jumper E1 and E2 links connect pins 2 and 3,
thus passing both shield connections through.
On the alternative version, the shield connections are
closed when jumpers JP1 and JP2 links are fitted.
75
Ω
BNC
Connectors
1
JP1 / JP2
Alternative
Jumper Type
E2
1
2
3
3
2
1
E1