AROW Series
Data Diode
Installation and Operation
9-8
Firmware update:Finishing
Check firmware update has been applied
To load the content of the updated flash, AROW needs to be power
cycled.
Once the power has been re-applied, check that the version number,
revision number and commit number match the numbers on the bin file
you have used by running ./control_AROW_tcp.py -H <IP address of
control port> -s for example:
./control_arow_tcp.py -H 192.168.2.223 -s
part number: a0a00112
serial number: 01342d4aa73f0ca2
firmware version: 1 revision: 0 commit: 0x0000000
...
If the numbers do not match try programming the flash again. for any
further help, contact SomerData support.
Secure Top Cover
Remove the power IEC connector form AROW
re-place the cover, lining up the screw holes with the holes in the cover.
Fasten the 24 screws using a 2mm Allen key (Hex key).
re-install the system in your network