AROW Series
Data Diode
Installation and Operation
8-9
Table 8-5 commit number (0x0004)
Valid from firmware V0R2
Bit
Field
mode
Default
Value
Description
27:0
commit
RO
0x0000000
Revision system (git)
commit number
Table 8-6 hardware status (0x0005)
Valid from firmware V0R5
Bit
Field
mode
Default
Value
Description
0
Module is
High
RO
-
Module is in a high side slot.
0 = module is in a low side
(dirty) slot.
1
Module in
live slot
RO
-
Module is in a live slot. 0 =
module is in a backup slot
2
Module is
live
RO
-
Module is currently the live
module. (even if it is in a
backup slot). 0= the other
module is a live module and
we are backup.
3
Live-backup
link is up
RO
-
Link between live and
backup modules is up.
16
Stand-alone
module
RW
0x0
1 = Module is live and is for
use in non redundant
systems. 0 = Module to be
used in a redundant system;
it expects another module
alongside it and will produce
or receive both a live and
backup stream of optical
data.
17
Reset
live/backup
link
RW
0x0
Reset the Live/backup
duplex link
Содержание AROW Series
Страница 2: ...AROW Series Data Diode Installation and Operation ...
Страница 8: ...AROW Series Data Diode Installation and Operation 1 5 15 INDEX 15 1 ...
Страница 18: ...AROW Series Data Diode Installation and Operation 4 3 ...
Страница 69: ...AROW Series Data Diode Installation and Operation 11 4 This page intentionally blank ...