AROW Series
Data Diode
Installation and Operation
7-3
Failure condition Failure
detection
speed (typical)
Possible Data
corruption?
Further action required
Unit Service
required
Low side Loss of
Gigabit Ethernet
link
1 Second
No
Restore the Gigabit Ethernet link
No
High side Loss of
Gigabit Ethernet
link
1 Second
Only If high side buffer
over-runs
If AROW is being used at full bandwidth, the
sending application may need to be throttled
back to help the data buffer to get back to a
safe level
No
Low side module
failure
100
microseconds
If data is being
transferred over optics as
module fails
The failed module should be replaced as
soon as possible.
No
High side module
failure
100
microseconds
If data is being
transferred over optics as
module fails
The failed module should be replaced as
soon as possible.
Once the failure has been resolved, the
optical links will have to be reset.
No
AC /DC Power
unit failure
NA
No
The AROW unit will have to be serviced as
soon as possible.
Yes
Optical link failure 100
microseconds
If transfer as optics fails The AROW unit will have to be serviced as
soon as possible.
Yes