Light Codes:
Newer SOMAT systems employ a micro-computer to control many of the unit
functions. If a fault or overload is detected, the system will flash a series of codes by lights
located either on the pushbutton station OR on the panel enclosure itself. Below is a list
of the most commonly used for close coupled machines.
Solid
Green
: All safeties are latched and secure, system is ready to run
Flashing
Green
: System is in timed stop mode, extractor will spray, after less than
10 minutes system will shut down.
Slow flashing
Green
: Unit drain is open, press
Green
pushbutton to close drain.
Two
Green
flash, pause, and repeat: All safeties are latched and secure, tank is
filling.
Solid
Red
: One of systems 3 motors is overloaded and must be reset
Flashing
Red
: Lid switch on pulper or extractor lid is open, shut lid to resume
normal operation