SHUTDOWN PROCEDURES -
The following shutdown procedures must be followed
prior to performing necessary cleaning and maintenance duties.
1. Allow the Pulper to operate approximately fifteen minutes after the last waste
has been fed.
2. Depress black “
TIMED STOP
” pushbutton once to engage spray rinse system,
system will then time out on its own. The Pulper will stop when the shutdown
timer has timed out.
3.
Press “
DRAIN EMPTY
” pushbutton on panel door to drain system. This
pushbutton will
DRAIN ONLY
, you must press
GREEN
start button to close
drain. This will pre-fill the system again.
4.
Lock in the
STOP
button lock and turn power off to perform any cleaning or
maintenance.
5.
Refer to the applicable Pulper and Hydra-Extractor
maintenance sections of
this manual for daily, weekly and long term shutdown cleaning procedures and
maintenance instructions.
***To ensure all food waste is removed from the extractor, you can use Styrofoam plates
as a cleaning agent for the unit. The Styrofoam will force out the majority of food waste
leaving only Styrofoam. Run the plates as you would any waste, and continue until
nothing but Styrofoam exits the extractor. We do not recommend using cardboard as it
will dry out and create a very hard obstruction in the extractor which could cause motor
overload on restart.***
*Print sequence of operation on next page for display for operators.*
Содержание SPC-75S
Страница 12: ...Installation ...
Страница 16: ...MOUNTING DETAIL OF TROUGH ...
Страница 21: ...FOR REFERENCE ONLY ...
Страница 22: ...Start Up ...
Страница 26: ...Operation ...
Страница 32: ...CLEANING YOUR SYSTEM ...
Страница 38: ...MAINTENANCE ...
Страница 49: ...TROUBLESHOOTING ...
Страница 56: ...REPLACEMENT PARTS EXPLODED VIEWS ...
Страница 57: ......
Страница 60: ......
Страница 62: ......