proved by submitting the technical report of the entity responsible for it, or alternatively by registering
them in the instruction manual in the dedicated section.
3.12
In order to avoid damage to the equipment caused by overpressure, safety elements such as
pressure relief valves and / or thermal discharge valves, if applicable, as well as an expansion vessel
fitted to the installation, shall be ensured at the time of installation and its correct functioning must be
ensured. It should be noted that: the valves referenced must have a value equal to or less than the
pressure supported by the equipment; there shall be no cut-off valve between the equipment and its
safety valve; provision should be made for a systematic preventive maintenance plan to attest to the
correct functioning of the said safety features; irrespective of the type of appliance, all safety valves
shall be channeled to drained sewage to prevent damage to the dwelling by water discharges. Product
Warranty does not include damages caused by non-channeling of water discharged by said valve.
3.13
In order to avoid damage to the equipment and attached pipes by galvanic corrosion, it is
advisable to use dielectric separators in the connection of the equipment to metal pipes whose
characteristics of the materials applied to this type of corrosion. Product Warranty does not include
damages caused by non-use of such dielectric separators.
3.14
The water or thermofluid used in the heating system (hydro toves, boilers, central heating
stoves, among others) must comply with the legal requirements in force, as well as guarantee the
following physical and chemical characteristics: absence of solid particles in suspension; low level of
conductivity; residual hardness of 5 to 7 degrees; neutral pH, close to 7; low concentration of
chlorides and iron; and absence of air inlets by depression or others. In case the installation enhances
automatic water make-up, it should consider upstream a preventive treatment system composed of
filtration, decalcification and preventive dosing of polyphosphates (scale and corrosion), as well as a
degassing step, if necessary. If in any circumstance any of these indicators show values that are not
recommended, the Warranty will cease to have effect. It is also compulsory to place a non-return
valve between the automatic filling valve and the mains water supply, and that said supply always has
constant pressure, even with a lack of electricity, not depending on lift pumps, autoclaves, or others.
3.15
Except as expressly provided by law, a warranty intervention does not renew the warranty
period of the Product. The rights arising from the Warranty are not transferable to the purchaser of
the Product.
3.16
The equipment must be installed in accessible places and without risk to the technician. The
means necessary for access to them shall be made available by the Buyer, and the Buyer shall be
responsible for any charges arising therefrom.
3.17
The Warranty is valid for the Products and equipment sold by Solzaima SA solely and
exclusively within the geographical and territorial zone of the country where the Product was sold by
Solzaima.