24
3
26_05_01_0287
1.6 Spare parts
2
Item
Part no.
Immersion heater 2.0 kW (1)
16 58 01
Flange gasket (4)
15 83 40
Hexagon screw (5)
08 82 46
Protective anode M8 (3)
06 91 82
Controller (7)
15 04 14
Controller knob
14 10 99
Limiter
16 61 79
Solar control PCB (6)
16 58 44
Solar control unit collector sensor 16 58 46
Cylinder sensor
17 00 05
1.7 Speci
Þ
cation
Type
SolvisMini
Capacity
gross/net l 150/146
Weight, dry
kg 82
Permiss. op. pressure
bar 6
Immersion heater
kW 2.0
Heat exch. surface area m² 1.2
Cold water/DHW connection G ½"
Heat exch. connections
G ¾" A
IP protection
24
Pump 812)
Wilo St20/4-3C
Min. insulation thickness mm 40
Dimensions H/W/D
mm 1100 x 510 x 510
9
1
5
Drain (8)
1.5 Maintenance and care
A damp cloth is sufficient for
cleaning
the
casing. Never use scouring or solvent-based
cleaning agents.
Maintenance
2
Only ask quali
Þ
ed contractors to
carry out maintenance.
Before any work on the equipment,
disconnect all poles from the mains.
Check the protective anode (3) after the
first two years and replace, if required.
After a replacement the contractor will
determine the interval for further checks.
Replace the flange gasket (4).
Descale the flange only after its removal.
Never treat the casing and the protective
anode with descaling agents.
!
Safety equipment:
5
Always maintain the stipulated dimensions
when replacing the controller or the high
limit safety cut-out.
Check the safety assembly regularly.
Draining the cylinder
3
4
5
The equipment is drained via the safety
assembly or via the drain (8) at the heating
flange.
Close the shut-off valve in the cold water
supply.
Fully open the hot taps at all draw-off
points.
Open the rotary cap of the safety valve
(13) anti-clockwise towards “Checking” or
open the drain valve.
The high limit safety cut-out can
respond at temperatures below
–15 ºC.
Hot water can be expelled during draining.
4
Solv collector
Solar station (standard delivery) (16)
Air vent valve (9)
Collector sensor (10),
SolvisMini standard delivery
Collector array (11)
Safety assembly (18)
Draw-off points (17)
Safety-valve (13)
Drip tank (14)
Pump (12)
26_05_01_0409