48 UM0005_ASW 8-20K-LT-G2_EN_V03_1121
4. Release and remove all DC connectors. Insert a flat-blade
screwdriver or an angled screwdriver (blade width: 3.5 mm)
into one of the slide slots and pull the DC connectors out
downwards. Do not pull on the cable.
5. Release and disconnect the AC connector. Rotate the socket
element counterclockwise to open.
Danger to life due to electric shock when touching exposed
DC conductors or DC plug contacts if the DC connectors are
damaged or loose
The DC connectors can break or become damaged, become
free of the DC cables, or no longer be connected correctly if
the DC connectors are released and disconnected incorrectly.
This can result in the DC conductors or DC plug contacts
being exposed. Touching live DC conductors or DC plug
connectors will result in death or serious injury due to electric
shock.
• Wear insulated gloves and use insulated tools when working
on the DC connectors.
• Ensure that the DC connectors are in perfect condition and
that none of the DC conductors or DC plug contacts are
exposed.
• Carefully release and remove the DC connectors as
described in the following.