CAMERA INSTALLATION – INSPECTION
1. CAMERA INSTALLED – INSPECTION
Prior to each flight with the camera installed, an inspection of the installed
components must be performed.
A. Verify that the camera cables are securely connected to the camera.
B. Verify that the dovetail locking blocks are tightened in place and that the lock pin
is installed.
C. Verify that the upper dovetail bolts are tight and safety wired.
D. Check the security of the installed camera pod.
E. Verify that the left aileron trim tab is secured and adjusted up and the right trim
tab is secured and adjusted down. The trim tabs must be set at equal but
opposite angles from 0° to 9° dependant on the size of payload installed at the
wing mount location.
F. Verify that the correct placards are installed in the passenger compartment of the
aircraft. Refer to S2060A Soloy Wing Mount Camera Pilot’s Operating Handbook
Supplement Section 2 for the placards and their locations.
2. CAMERA REMOVED – INSPECTION
When the camera is removed verify that the trim tabs are secured at 0° and that the
correct cover is installed at wing access panel 510YBS (no camera cable hole).