Alarm Behavior Table 

Fault Description 

Line Mode 

Backup Mode 

Fault 
Code 

No. of Beeps 

AC Output 

No. of Beeps 

AC Output 

Overload 1 (V

out

<195V) 

OFF 

Output RMS voltage low 

OFF 

Over temperature/Short-circuited 

OFF 

Fan locked 

ON 

OFF 

Battery voltage high 

ON 

Overload 2 (V

out

195V; P

out

80% rated half-wave load) 

ON 

OFF 

AC output abnormal 

OFF 

Output voltage RMS high 

OFF 

Peak output voltage high 

OFF 

Utility connection error 

OFF 

OFF 

PV current high 

1BP/s 

ON 

1BP/s 

ON 

11 

Solar charger over-temperature 

1BP/s 

ON 

1BP/s 

ON 

12 

Battery voltage high for Solar 
charger 

1BP/s 

ON 

1BP/s 

OFF 

13 

PV over-voltage 

1BP/s 

ON 

1BP/s 

ON 

14 

NTC opened 

1BP/s 

ON 

1BP/s 

ON 

15 

Solar charger MOSFETs /Relay 
damaged 

1BP/s 

1BP/s 

16 

Note: please contact your service representative in the event the alarm behavior is 

not included in the table above. 

 

 

 

 

 

 

 

 

 

 

 

Содержание PowerBack PB1000S

Страница 1: ...INSTALLATION AND OPERATION MANUAL PowerBack PB1000S PB2000S WITH SOLAR CHARGE CONTROLLER...

Страница 2: ...direct sunlight rainfall or snow Before performing any maintenance on the product please disconnect all power sources AC mains batteries solar panel to avoid the risk of electrical shock Do not attemp...

Страница 3: ...ation Acts of third parties atmospheric discharges excess voltage chemical influences natural wear and tear and for loss and damage in transit Improper testing operation maintenance adjustment repair...

Страница 4: ...9 2 3 Batteries 9 2 4 PV solar string 11 2 5 Connect AC Input Cables and Loads 12 2 6 AC Input Voltage Range Selector 12 OPERATION 13 3 1 Standby Charging Mode 13 3 2 Operation Modes after powered on...

Страница 5: ...power from AC mains as long as sufficient sunlight is present The battery can be charged by both AC mains and PV solar string with intelligent charging control Key features Automatic line to battery s...

Страница 6: ...5 1 1 Product Outlook Front Panel Rear Panel PV Input terminals AC output receptacle AC input receptacle Battery terminals DC Fan...

Страница 7: ...generator presents If unit is on wide mode WIDE will be lighted else NARROW will be lighted This icon is showed when PV solar system presents The icon indicates level of remaining battery capacity Th...

Страница 8: ...r to Section Troubleshooting LED Indicators The operation mode of the inverter can be easily told by LED indicators Please see the table below for details LED indicators Information Green Line Mode 1...

Страница 9: ...mode To go to the next selection page To confirm the selection in setting mode 1 2 Typical Application A typical application diagram for home and office applications is as shown below The inverter ca...

Страница 10: ...carry the inverter 2 The location of installation shall allow the user to read the LCD easily 3 Two screws shall be firstly fixed on the wall distance as shown below so that the inverter can be hung...

Страница 11: ...the inverter Connect the battery cables to the inverter s battery terminals as shown below Connect with single battery Make sure the battery voltage meets the inverter s specification Connect with mu...

Страница 12: ...of PV panel so that the operational voltage and current fall within the allowed range of the inverter as set out in the specification Please do not use PV panel which requires one terminal connected...

Страница 13: ...sensitive to the voltage disturbance on the AC input and the input voltage range is set at 170 280VAC while output voltage follows input voltage B WIDE setting Set the selector to WIDE when connected...

Страница 14: ...called Standby Charging Mode When AC input cable and battery is connected the inverter will enter into Standby Charging Mode and LCD will be turned on with the following display If PV string is also c...

Страница 15: ...peration mode according to the condition of AC input and PV input as shown in the table below LINE MODE 1 AC input power is present but there is no PV power e g night time Load is supplied by AC input...

Страница 16: ...deemed an energy saving operation BACKUP MODE 1 Both AC input and PV input are absent The backup power to load comes only from battery The backup time is determined by the capacity of battery BACKUP M...

Страница 17: ...Menus The LCD display content will be changed in turns by pressing button The selectable information is switched as below order PV input voltage PV input current AC input voltage battery voltage outp...

Страница 18: ...to the loads as first priority Solar and battery energy will provide power to the load only when utility power is not available SbU Solar energy provide power to the loads as first priority If solar e...

Страница 19: ...solar and utility chargers Max charging current utility charging current solar charging current Options in POWERBACK PB1000S model 20A 30A 40 50A 60A default 70A 80A Options in POWERBACK PB2000S model...

Страница 20: ...60 load 20 0V for 24V model 60 load 21 0V for 24V model 60 load Setting range is from 10 0V to 12 0V for 12V model 20 0V to 24 0V for 24V model Increment of each click is 0 2V per step 10 LED light c...

Страница 21: ...18 Frequency 50Hz or 60Hz Auto detection Output Waveform Modified Sine wave EFFICIENCY 80 OVERLOAD PROTECTION 1min 110 20s 120 0s 150 PROTECTION Discharge over charged over loading over temperature sh...

Страница 22: ...batteries Power button is not pressed Press and hold the power button Mains are normal but works in backup mode AC input is absent Check the connection of AC input Backup time is short Overloading Dis...

Страница 23: ...N 6 OFF 6 AC output abnormal 7 OFF 7 Output voltage RMS high 8 OFF 8 Peak output voltage high 8 OFF 8 Utility connection error 9 OFF 9 OFF 9 PV current high 1BP s ON 1BP s ON 11 Solar charger over tem...

Страница 24: ...is Vstring V1 V2 V3 V4 Istring I1 I2 I3 I4 When connecting the above PV string in parallel the max voltage and current of the total string is Vtotal Vstring1 Vstring2 Vstring3 Vstring4 Itotal Istring1...

Страница 25: ...ut current of the solar battery charger 65A for all model Example 1 How to connect POWERBACK PB1000S model to PV panels with the following parameters Pmax 150W Voc 21 6V Isc 8 75A Vmp 18V Imp 8 2A 1 M...

Страница 26: ...anel in parallel is 7 2 Operating Voltage Range is 30 32V One PV panel Vmp 30 96V is between 30 32V max number of PV panel in series is 1 3 Taking 1 2 into consideration the optimized configuration is...

Страница 27: ...lity power only even when solar power presents 1 2 When utility is down As soon as the utility is down the inverter enters into Backup Mode and checks both solar power and battery s status If solar po...

Страница 28: ...the setting point in program 5 utility will then take over to support the loads and charge the battery 3 2 When utility is down The behavior is the same as 1 2 Advantages Disadvantages The utilizatio...

Страница 29: ...hen utility is normal Solar energy and utility will charge battery at the same time 4 2 When utility is down Solar energy and utility will charge battery Summary Whether setting which option as charge...

Отзывы: