BACKUP MODE 3
AC input is absent and PV power is strong enough to not only support the load but
also charge the battery.
As long as the PV power persists, the load can be powered continuously without
consuming power from battery.
3.4 Fault Mode
Inverter enters into Fault Mode when there is a fault event. The fault icon will be
shown with a fault code. Please refer to fault code table in “Troubleshooting”
section.
3.5 LCD Setting
(1) Display Menus
The LCD display content will be changed in turns by pressing button. The
selectable information is switched as below order: PV input voltage, PV input
current, AC input voltage, battery voltage, output voltage, output frequency, load
percentage, load VA value, load watt value. LCD will return to default LCD display
after 1 minute. IF users want to return to default LCD display immediately, please
press
button.
(2) Setting Menus
After pressing and holding button for more 2 seconds to enter setting mode,
press button for 1 second to select setting programs, then press button to
select program option, then press
button to confirm the selection.