10
Connect the battery cables
The gauge of battery cables shall be no less than 6 AWG with 105˚C rating.
No matter how the batteries are connected (in series or in parallel), make sure
the cables’ terminal voltage is consistent with the inverter’s specification(12V
for POWERBACK PB1000S model and 24V for POWERBACK PB2000S model).
It’s recommended to cover the battery terminals during the connection.
Check the polarity of cables before connecting to the inverter.
Connect the battery cables to the inverter’s battery terminals as shown below.
Connect with single battery
Make sure the battery voltage meets the inverter’s specification
Connect with multiple batteries
While connecting multiple batteries, use the same brand/type for all
batteries. Do not mix the battery bank with different brand/type of
batteries.
The user may connect the batteries in series in order to double the voltage
connected to inverter. The diagram below illustrate how to connect two 12V
batteries in series to make up 24V (for PowerBack PB2000S)
12V PowerBack PB1000S model
24V PowerBack PB2000S model
PowerBack
PowerBack