EZL-200F User
’
s Manual Ver. 2.1
Sollae Systems Co., Ltd.
- 12 -
http://www.sollae.co.kr
Setting of EZL-200F
EZL-200F uses ezConfig as it’s a configuration program. ezConfig is for MS Windows,
and this is comfortable to use because it doesn’t need installation. First, search your
EZL-200F via network. All the values of parameters were set to default values in the
factory. To apply it to your system, proper values should be set via ezConfig. Major
parameters’ default values are listed on below table. To implement this simple test,
keep these values without any changes.
Table 2-1 default values of Major parameters
Name
Default Values
Network
Local IP Address
10.1.0.1
Subnet Mask
255.0.0.0
Option
TELNET
Checked
IP Address Search
Checked
TCP/IP
Communication mode
TCP Server
Local Port
1470
Serial Port
(COM1)
Serial Type
RS232
Baud Rate
19,200bps
Parity
NONE
Data Bits
8
Stop Bit
1
Flow Control
NONE
Users can download the latest version of ezConfig on the [Support] >> [Download] >>