2. Safety & Warning
WARNING:
The RHl-5G Series does not support parallel (three- and single-phase)
operation on the AC-BACKUP port. Parallel operation of the unit will void the
warranty.
3 Phase LOAD
1 Phase LOAD
WARNING:
Please refer to the specification of the battery before configuration.
2.3 Notice For Use
. 6.
The inverter has been constructed according to the applicable safety and technical
guidelines. Use the inverter in installations that meet the following specifications ONLY:
1. Permanent installation is required.
2. The electrical installation must meet all the applicable regulations and standards.
3. The inverter must be installed according to the instructions stated in this manual.
4. The inverter must be installed according to the correct technical specifications.
3. Overview
3.1 Screen
Solis RHl-5G Series adopts 7 inch color screen, it displays the status, operating information and
settings of the inverter.
3.2 Keypad
There are four keys in the front panel of the inverter (from left to right):
ESC, UP, DOWN and ENTER keys. The keypad is used for:
• Scrolling through the displayed options (the UP and DOWN keys);
■ Access and modify the settings (the ESC and ENTER keys).
0 0 0 0
ESC
UP
DOWN
ENTER
Figure 3.2 Keypad
3.3 Terminal Connection
Solis RHl-5G Series inverter is different from normal on-grid inverter, please refer to the
instructions below before start connection.
Dry Contact Port (reserved)
Battery Communication Connection (CAN)
DC Switch (Optional)
COM Port
PV Module In ut
AC Connection to Grid
Battery Connection
AC Connection to BACKUP
Figure 3.3 Front Panel Display
WARNING:
Please refer to the specification of the battery before configuration .
.7.