5. Operation
5 .6 . 7 .3 Fail Safe ON/O F F
When this Failsafe function is ON, the inverter will shutdown once it loses
communication with the meter in case of any backflow power exceeding the limit.
FailSafe ON/OFF
201 5-02-23 19 35
....
.
............
.
....
.
....
Y E S = < E N T > N O = < E S C >
Figure 5.4 7 FailSafe ON/OFF
5 .6 .8 H M I U pdate
. 48.
This function is used to update HMI software.
Values are for reference only.
HMI Update
201 5-02-23 1 9 35
The Current Version: FO
CAN C E = < E S C > UPDAT E SYSTE M = < E N T >
Figure 5.48 H M I Update
5. Operation
5 .6 .9 DSP U pdate
This function is used to update DSP software.
Values are for reference only.
DSP Update
201 5-02-23 1 9 35
The Current Version:00
CAN C E = < E S C > UPDAT E SYSTE M = < E N T >
Figure 5.49 DSP Update
5 .6.10 Baud Rate RS485
This function is to change the internal communication Baud rate.
BaudRate RS485
201 5-02-23 1 9 35
Baud Rate :
i@1111
Y E S = < E N T > N O = < E S C >
Figure 5.50 Baud Rate RS485
WARNING:
This function is for maintenance personnel only, wrong operation
will prevent the inverter from working properly .
.49.