5. Operation
5. 6 . 6 .2 Battery Select
.40.
This product is compatible with the following battery modules:
Brand
Model
Setting
BYD
Box Pro 2. 5-13.8
Select " B-BOX"
LG Energy
RESU 3.3/6.5/10/13 (CEI 0-21)
Select "LG Chem"
Solution
US2000(CEI 0-21 )/US3000(CEI 0-21 )/
Pylontech
ForceL 1 (CEI 0-21 )/ForceL2(CEI 0-21 )/
Select " Pylon"
Phantom-SIU S2000C/US3000C/U P5000
Dyness
Powerdepot/Powerbox/B4850
Select "Dyness"
Pu red rive
48V-1 00Ah
Select " Pu red rive"
AOBOET
AOBOET U h ome-LFP 6.BkWh
Select "AoBo"
WECO
5K3-R20
Select "WECO"
Jiawei
Home E 1 1
Select "Jiawei"
Soluna
4K PACK
Select "Soluna"
Highstar
HS D5870
Select "Highstar"
Freedom
Freedom Won Lile
Select " Freedom"
KODAK
FL5.2
Select "KODAK"
FOX
LV5200
Select " FOX"
UZ Energy L051100-A
Select "CATL"
GSL
48V-100Ah
Select "GSL"
Zeta
51.2V-1 00Ah
Select "Zeta"
NOTE:
If hybrid inverter is not connected to a battery, select "No Battery" to
avoid alarms.
For above compatible battery modules, Only two parameters need to be defined:
* OverDischg SOC (10%-40%, default 20%)
--Inverter will not discharge the battery when the OverDischg SOC is reached.
Battery self-discharge is unavoidable,SOC may go lower than the limit if the battery
can't get charged for a long period of time.
* ForceCharge SOC (5%-OverDischg SOC, default 10%)
--To prevent the battery going into sleep mode, when the ForceCharge SOC is reached,
inverter will charge the battery using the power from either PV or Grid.
5. Operation
Battery Select
201 5-02-23 1 9 35
Battery Module:
■
=1=1•131'
■
Y E S = < E N T > N O = < E S C >
Figure 5.33 Battery Select
Battery Select
201 5-02-23 1 9 35
averDischg sac :
1,j, .. ,11Jr4'
Y E S = < E N T > N O = < E S C >
Figure 5.34 Over Discharge SOC.
Battery Select
201 5-02-23 1 9 35
ForceCharge sac :
111111'4'
Y E S = < E N T > N O = < E S C >
Figure 5.35 ForceCharge SOC
.41.