Model 464 Electronic Pump Control Unit User Guide
Page 7
2.5.2 Create Setting
To create a new setting, select “Create Setting” from the User Flow Rates
menu. Enter the new site name, drive/vent times, and pressure setting using
the cursor keys and +/- keys (see Edit Settings Section). Once you are finished
programming the settings, use the cursor key to highlight “Save” and press OK.
Figure 2-13 Creating a New Site
Site:
Drive:
0s Set Pressure:
Vent: 0s 0psi
Create Setting
Save
4:59 Min
99%
2.6 Automatic Drive/Vent Cycles
Select the desired setting. To start the drive/vent cycles, use the cursor key to
highlight “Start” and press OK. When the Control Unit is running, the LCD will
display the progress of the vent and drive cycles. Pressing the OK button when
in running mode will stop the drive/vent cycles.
Figure 2-14 Running Mode
Site: W13 Landfill 37
Drive: 0 of 5s
Vent: 4 of 5 s
Saved Settings [1 of 10]
Stop
4:59 Min
99%
NOTE
While the drive/vent cycles are in
progress it is not possible to edit the
displayed site information or exit
the site menu. The only option is to
push OK, to stop the cycling.
NOTE
See Section 3.3 for help calculating
drive and vent times.